Numerical Analysis of Divergent Duct Integrated Blade Design in Axial Flow Compressor
Journal of Applied Fluid Mechanics · 01.07.2026 · 19 (7)
DOI: 10.47176/jafm.19.7.4240 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Fluid Mechanics, online erschienen am 01.07.2026. Verfasst von P. N. Vasanth Sudarshan und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Improving the aerodynamic stability and pressure-rise capability of highly loaded axial compressors remains a central challenge, where the boundary-layer separation, adverse pressure gradients, and tip-leakage interactions limit overall performance. Conventional geometric strategies such as sweep, lean, or endwall contouring provide incremental aerodynamic benefits to some minor extent. This study proposes a passive-flow modification in which internal divergent ducts are embedded within the rotor and stator blades of the single stage NASA Stage 35 compressor. The concept allows the fluid to pass through the implicit divergent ducts from leading still trailing edges without altering any external blade geometry. Three cases were evaluated to compare and understand the flow behaviour, pressure ratio improvements: (1) the unmodified baseline, (2) the stator-only divergent duct design, and (3) a fully modified rotor–stator implementation. Steady-state Reynolds-averaged Navier–Stokes simulations were performed using ANSYS Workbench 2020, based on high-fidelity CREO Parametric geometry, to evaluate aerodynamic performance, and the resulting pressure loads were mapped to a structural model to assess mechanical integrity. The fully modified case demonstrated substantial improvements, increasing the total pressure ratio from approximately 1.84 to over 2.10, raising mass-flow capacity by more than 12%. At the same design rotational speed (17,188 rpm), the static pressure rise increased by approximately 31%, and the pressure-rise coefficient improved from 0.477 in the baseline configuration to 0.624 in the fully modified case, indicating more effective diffusion and reduced aerodynamic losses. Structural evaluation confirmed the very negligible deformation and stresses well below titanium material limits. The peak von Mises stress remained below ~110 MPa, corresponding to a safety factor greater than five relative to the yield strength of typical titanium compressor alloys. Although the findings are based on steady numerical simulations at a single operating condition, the results indicate that the divergent-duct-integrated blade concept is a promising direction for future multi-stage optimization and experimental validation.
Zitieren
APA
Sudarshan, P. N. V., & Madhesh, D. (2026). Numerical Analysis of Divergent Duct Integrated Blade Design in Axial Flow Compressor. Journal of Applied Fluid Mechanics, 19(7). https://doi.org/10.47176/jafm.19.7.4240
Vancouver
Sudarshan PNV, Madhesh D. Numerical Analysis of Divergent Duct Integrated Blade Design in Axial Flow Compressor. Journal of Applied Fluid Mechanics. 2026;19(7). doi:10.47176/jafm.19.7.4240
BibTeX
@article{Sudarshan2026,
author = {Sudarshan, P. N. Vasanth and Madhesh, D.},
title = {Numerical Analysis of Divergent Duct Integrated Blade Design in Axial Flow Compressor},
journal = {Journal of Applied Fluid Mechanics},
year = {2026},
volume = {19},
number = {7},
doi = {10.47176/jafm.19.7.4240}
}
EUVIMED