EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Management and Outcomes of Cardiac Implantable Electronic Device Infections without Specialized Lead Extraction Tools in a Resource-Limited Setting: A Single-Center Retrospective Study

Arshad Ali, Muhammad Sarim Ansari, Ahmed Mohammed Ahmed, Romana Pirah, Faisal Qadir, Ghazala Irfan, Azam Shafquat

Pakistan Heart Journal · 01.05.2026 · 59 (2) · 362-370

DOI: 10.47144/phj.v59i2.3509 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pakistan Heart Journal, online erschienen am 01.05.2026. Verfasst von Arshad Ali und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate management strategies and clinical outcomes of patients with CIED infections treated without specialized lead extraction tools in a resource-limited tertiary care setting. Methodology: This single-center retrospective study included patients admitted with CIED infection at the National Institute of Cardiovascular Diseases (NICVD), Karachi, Pakistan, between June 2023 and October 2025. Patients were categorized according to management strategy: Group 1 (no complete hardware removal) and Group 2 (complete hardware removal). Follow-up was conducted through outpatient clinic visits and structured telephone interviews. Clinical outcomes included procedural success, in-hospital mortality, infection persistence, recurrence, and follow-up mortality.

Results

A total of 53 patients were analyzed (mean age 58.2 ± 17.2 years; 56.6% male). Complete hardware removal was achieved in 37 patients (69.8%), while 16 patients (30.2%) underwent partial removal or debridement only. Of 99 indwelling leads, 71 (71.7%) were successfully extracted using manual traction techniques. Median dwell time of explanted leads was 136 days [19–1198]. In-hospital mortality occurred in 3 patients (5.6%). During follow-up (median 173 days), persistence of infection occurred in 4 patients (8.5%), and recurrence was observed in 3 patients (6.4%). Infection persistence was significantly more frequent in patients without complete hardware removal.

Conclusion

In this resource-limited setting, complete hardware removal was feasible in approximately two-thirds of CIED infections without specialized extraction tools and was associated with lower infection persistence. While outcomes appear acceptable, findings should be interpreted cautiously given the retrospective design and limited sample size.

Zitieren

APA

Ali, A., Ansari, M. S., Ahmed, A. M., Pirah, R., Qadir, F., Irfan, G., & Shafquat, A. (2026). Management and Outcomes of Cardiac Implantable Electronic Device Infections without Specialized Lead Extraction Tools in a Resource-Limited Setting: A Single-Center Retrospective Study. Pakistan Heart Journal, 59(2), 362-370. https://doi.org/10.47144/phj.v59i2.3509

Vancouver

Ali A, Ansari MS, Ahmed AM, Pirah R, Qadir F, Irfan G, et al. Management and Outcomes of Cardiac Implantable Electronic Device Infections without Specialized Lead Extraction Tools in a Resource-Limited Setting: A Single-Center Retrospective Study. Pakistan Heart Journal. 2026;59(2):362-370. doi:10.47144/phj.v59i2.3509

BibTeX
@article{Ali2026,
  author = {Ali, Arshad and Ansari, Muhammad Sarim and Ahmed, Ahmed Mohammed and Pirah, Romana and Qadir, Faisal and Irfan, Ghazala and Shafquat, Azam},
  title = {Management and Outcomes of Cardiac Implantable Electronic Device Infections without Specialized Lead Extraction Tools in a Resource-Limited Setting: A Single-Center Retrospective Study},
  journal = {Pakistan Heart Journal},
  year = {2026},
  volume = {59},
  number = {2},
  pages = {362--370},
  doi = {10.47144/phj.v59i2.3509}
}
Kostenlos starten →