Analisis Struktur Bangunan Bertingkat Terhadap Beban Gempa Pada Bangunan Rumah Sakit (Studi Kasus: RS Primaya-Tangerang, Banten)
Journal of Sustainable Civil Engineering (JOSCE) · 28.10.2026 · 8 (02) · 446-461
DOI: 10.47080/josce.v8i02.4895 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Sustainable Civil Engineering (JOSCE), online erschienen am 28.10.2026. Verfasst von Afiatur Rizki Ramadhan und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Traffic This study evaluates the seismic response of a multi-storey hospital building at Primaya Hospital, Tangerang, Banten, Indonesia. Considering the importance of maintaining structural performance in essential healthcare facilities, the assessment focuses on the building’s dynamic characteristics, inter-story drift, and second-order effects under earthquake loading. A quantitative case-study approach was employed by modelling the eleven-storey reinforced concrete structure using ETABS. The structural evaluation was conducted through dynamic response spectrum analysis in accordance with Indonesian seismic design provisions, particularly SNI 1726:2019. The results indicate that the fundamental periods in the X and Y directions are 0.743 s and 0.977 s, respectively, while the first two vibration modes are predominantly translational and the third mode exhibits torsional behaviour. The cumulative modal mass participation reaches 100% in both horizontal directions by the thirty-fifth mode. The maximum inter-story drifts are 16.001 mm in the X direction and 28.398 mm in the Y direction, both of which remain below the reported allowable limit of 30.769 mm. Furthermore, the P-Delta coefficients are 0.0064 and 0.0117 in the X and Y directions, respectively, indicating that the Y direction exhibits a comparatively greater second-order effect. Overall, the evaluated parameters satisfy the corresponding criteria reported in the analysis, although the Y direction requires greater attention in structural assessment. These findings provide a basis for understanding the seismic response of the investigated hospital building. However, the results should not be interpreted as comprehensive evidence of building safety or post-earthquake hospital functionality, since member capacity, non-structural components, and essential utility systems were beyond the scope of this study.
Zitieren
APA
Ramadhan, A. R., & Naibaho, P. R. T. (2026). Analisis Struktur Bangunan Bertingkat Terhadap Beban Gempa Pada Bangunan Rumah Sakit (Studi Kasus: RS Primaya-Tangerang, Banten). Journal of Sustainable Civil Engineering (JOSCE), 8(02), 446-461. https://doi.org/10.47080/josce.v8i02.4895
Vancouver
Ramadhan AR, Naibaho PRT. Analisis Struktur Bangunan Bertingkat Terhadap Beban Gempa Pada Bangunan Rumah Sakit (Studi Kasus: RS Primaya-Tangerang, Banten). Journal of Sustainable Civil Engineering (JOSCE). 2026;8(02):446-461. doi:10.47080/josce.v8i02.4895
BibTeX
@article{Ramadhan2026,
author = {Ramadhan, Afiatur Rizki and Naibaho, Pio Ranap Tua},
title = {Analisis Struktur Bangunan Bertingkat Terhadap Beban Gempa Pada Bangunan Rumah Sakit (Studi Kasus: RS Primaya-Tangerang, Banten)},
journal = {Journal of Sustainable Civil Engineering (JOSCE)},
year = {2026},
volume = {8},
number = {02},
pages = {446--461},
doi = {10.47080/josce.v8i02.4895}
}
EUVIMED