Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) for Pseudophakic Bullous Keratopathy Secondary to a Retained Baikoff Anterior Chamber IOL with Synechiated Haptics and Traumatic Iridodialysis: A Case Report
Journal of Ophthalmology and Advance Research · 21.06.2026 · 7 (2) · 1-7
DOI: 10.46889/joar.2026.7210 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Ophthalmology and Advance Research, online erschienen am 21.06.2026. Verfasst von Pablo Tejada González und 10 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
Purpose
To report the surgical management of late-onset Pseudophakic Bullous Keratopathy (PBK) in an eye with a Baikoff-type angle-supported Anterior Chamber Intraocular Lens (AC-IOL) with all three haptics synechiated to the peripheral iris stroma, in the context of a pre-existing traumatic superior iridodialysis.
Methods
A 72-year-old male with a history of traumatic cataract and superior iridodialysis who had undergone extracapsular cataract extraction with implantation of a three-haptic Baikoff-type AC-IOL approximately 30 years prior presented in 2021 with decreased visual acuity. Best-Corrected Visual Acuity (BCVA) was Hand Motions (HM) in the affected eye. Diffuse corneal edema (central corneal thickness 838 µm) with bullous keratopathy unresponsive to medical therapy was diagnosed. Slit-lamp examination revealed synechiae of all three IOL haptics to the peripheral iris stroma, precluding safe explantation. Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) was performed retaining the AC-IOL in-situ.
Results
Intraoperative air tamponade was achieved, but the air bubble migrated to the posterior chamber through the superior iridodialysis in the immediate postoperative period. Despite the absence of sustained anterior chamber air tamponade, the endothelial graft remained adherent and bullous keratopathy resolved. At the final follow-up visit (6 months postoperatively), BCVA had improved to 0.1 (20/200), Intraocular Pressure (IOP) was 14 mmHg and progressive corneal clearing was documented on biomicroscopic examination and Anterior Segment Optical Coherence Tomography (AS-OCT).
Conclusion
DSAEK may be considered a viable surgical option for PBK secondary to retained AC-IOLs when explantation carries prohibitive risk. The presence of iridodialysis, though complicating air tamponade, does not necessarily preclude successful graft adhesion. The inherent rigidity of the DSAEK lenticule may confer an advantage over DMEK in anatomically complex anterior segments.
Zitieren
APA
González, P. T., Ramos, J., Aramburu, J., Herrero, I., Camara, E. D. L., Núñez, J., Iglesia, C., Arranz, A., Jimenez, P., Pérez, D., & Ibáñez, J. (2026). Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) for Pseudophakic Bullous Keratopathy Secondary to a Retained Baikoff Anterior Chamber IOL with Synechiated Haptics and Traumatic Iridodialysis: A Case Report. Journal of Ophthalmology and Advance Research, 7(2), 1-7. https://doi.org/10.46889/joar.2026.7210
Vancouver
González PT, Ramos J, Aramburu J, Herrero I, Camara EDL, Núñez J, et al. Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) for Pseudophakic Bullous Keratopathy Secondary to a Retained Baikoff Anterior Chamber IOL with Synechiated Haptics and Traumatic Iridodialysis: A Case Report. Journal of Ophthalmology and Advance Research. 2026;7(2):1-7. doi:10.46889/joar.2026.7210
BibTeX
@article{Gonzlez2026,
author = {González, Pablo Tejada and Ramos, Javier and Aramburu, Julia and Herrero, Inmaculada and Camara, Edurne de la and Núñez, Jorge and Iglesia, Carla and Arranz, Adrián and Jimenez, Patricia and Pérez, Diana and Ibáñez, Juan},
title = {Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) for Pseudophakic Bullous Keratopathy Secondary to a Retained Baikoff Anterior Chamber IOL with Synechiated Haptics and Traumatic Iridodialysis: A Case Report},
journal = {Journal of Ophthalmology and Advance Research},
year = {2026},
volume = {7},
number = {2},
pages = {1--7},
doi = {10.46889/joar.2026.7210}
}