EUVIMEDEUVIMED entdecken
Multizentrische Studie

A Multicenter Quality Audit Standardizing Esophageal Contouring in Postmastectomy Radiotherapy.

Manjinder Singh Sidhu, Deepak Abrol, Mohan Lal, Sumeet Aggarwal, Prachi Kalra, Rajesh Natte, Sushil Beriwal

ONCOLOGY · 12.03.2026 · 40 (2) · 10

DOI: 10.46883/2026.25921068 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift ONCOLOGY, online erschienen am 02.04.2026. Verfasst von Manjinder Singh Sidhu und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Mastectomy, Esophagus, Radiotherapy, Intensity-Modulated, Breast Neoplasms. Die Arbeit nennt 6 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Postmastectomy radiotherapy (PMRT) delivered with volumetric modulated arc therapy (VMAT) often results in higher esophageal doses than 3D techniques. Recent dose-toxicity studies recommend limiting the esophageal mean dose (Dmean) to less than 11 Gy, based on contours drawn from the cricoid to the carina. In contrast, our network’s autosegmentation delineates the entire esophagus, potentially underestimating dose to clinically relevant upper esophageal segments. This audit evaluated current dose-reporting practices and their implications for toxicity.

Methods

A multicenter retrospective audit of 43 consecutive PMRT cases (March 10 to May 5, 2025) across 8 centers was performed. All sites recontoured the esophagus using the cricoid-to-carina definition and submitted paired dosimetric values. One center reported grade 2 esophagitis rates in a separate clinical cohort before and after implementing the standardized contouring approach.

Results

Standardized contouring increased the networkwide mean esophageal dose from 6.1 Gy to 11.7 Gy. The median Dmean increased from 5.7 Gy to 9.6 Gy (P < .001). Sixteen of 42 evaluable patients (38.1%) exceeded the 11-Gy benchmark. In the separate cohort, grade 2 esophagitis decreased from 6 of 7 pre–standard operating procedure (SOP) to 0 of 7 post SOP (P = .004).

Conclusion

Standardizing esophageal contouring improves dose accuracy and is associated with reduced symptomatic esophagitis, supporting routine use of cricoid-to-carina contours to enhance toxicity risk assessment in PMRT. Keywords: Postmastectomy radiation therapy, esophageal contouring, dosimetric audit, radiation esophagitis, autosegmentation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MastectomyEsophagusRadiotherapy, Intensity-ModulatedBreast NeoplasmsRadiotherapy Planning, Computer-AssistedHumansRetrospective StudiesFemaleRadiotherapy DosageRadiotherapy, AdjuvantMiddle Aged

Zitieren

APA

Sidhu, M. S., Abrol, D., Lal, M., Aggarwal, S., Kalra, P., Natte, R., & Beriwal, S. (2026). A Multicenter Quality Audit Standardizing Esophageal Contouring in Postmastectomy Radiotherapy. ONCOLOGY, 40(2), 10. https://doi.org/10.46883/2026.25921068

Vancouver

Sidhu MS, Abrol D, Lal M, Aggarwal S, Kalra P, Natte R, et al. A Multicenter Quality Audit Standardizing Esophageal Contouring in Postmastectomy Radiotherapy. ONCOLOGY. 2026;40(2):10. doi:10.46883/2026.25921068

BibTeX
@article{Sidhu2026,
  author = {Sidhu, Manjinder Singh and Abrol, Deepak and Lal, Mohan and Aggarwal, Sumeet and Kalra, Prachi and Natte, Rajesh and Beriwal, Sushil},
  title = {A Multicenter Quality Audit Standardizing Esophageal Contouring in Postmastectomy Radiotherapy},
  journal = {ONCOLOGY},
  year = {2026},
  volume = {40},
  number = {2},
  pages = {10},
  doi = {10.46883/2026.25921068}
}
Kostenlos starten →