STUDY OF BEAM INJECTION INTO A MULTIFUNCTIONAL ACCELERATOR COMPLEX

P.I. Gladkikh, I.S. Guk

Problems of Atomic Science and Technology · 12.06.2026 · 90

DOI: 10.46813/2026-163-090 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Problems of Atomic Science and Technology, online erschienen am 12.06.2026. Verfasst von P.I. Gladkikh und 1 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

By modeling the beam motion in the recirculator of the MAC multifunctional accelerator complex, the machine’s acceptance criteria were evaluated, and an analysis of the permissible alignment errors of the structural elements was conducted. The possibility of correcting the influence of nonlinear magnetic field effects on the structural elements of the recirculator was demonstrated.