Comparison of Agatston Score Calculation Between the Syngo.Via Automated Method and the Manual Method in Non-Contrast Cardiac CT

Agil Abdul Muaziz, Hernastiti Sedya Utami, Pradana Nur Oviyanti, Supriyadi Supriyadi, Fathur Rahman Nugraha

Jurnal Health Sains · 30.04.2026 · 7 (4) · 95-106

DOI: 10.46799/jhs.v7i4.2826 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Health Sains, online erschienen am 30.04.2026. Verfasst von Agil Abdul Muaziz und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In clinical practice, the Agatston Score can be calculated manually or automatically using post-processing software such as Syngo.Via; However, the difference in absolute values between these methods can affect clinical interpretation. The study aimed to compare measurements of the Agatston Score obtained using the Syngo.Via automated method and manual calculations on non-contrast cardiac CT, with an emphasis on measurement differences, suitability, and reliability. A quantitative observational analytical study was conducted using retrospective no-contrast cardiac CT data from 20 subjects. The Agatston score is calculated automatically using Syngo.Via and manually using the Weasis software on the same image dataset. The difference in measurement was analyzed descriptively and tested for normality. Statistical differences were evaluated using the Wilcoxon Signed Rank Test, suitability was evaluated using Bland–Altman analysis, and reliability was evaluated using the Intraclass Correlation Coefficient (ICC) with a two-way mixed effect model and absolute suitability. Results showed that a difference between the method was not normally distributed and a statistically significant difference in the Agatston score was observed (p < 0.05). The Bland–Altman analysis showed that most of the differences were distributed around the zero line with a few outliers, while the ICC analysis revealed a very high reliability between the two methods (ICC = 1,000). In conclusion, the automatic and manual measurement of the Agatston Score showed excellent reliability and good agreement despite the statistically significant differences in absolute values, suggesting that the two methods could be compared.

Zitieren

APA

Muaziz, A. A., Utami, H. S., Oviyanti, P. N., Supriyadi, S., & Nugraha, F. R. (2026). Comparison of Agatston Score Calculation Between the Syngo.Via Automated Method and the Manual Method in Non-Contrast Cardiac CT. Jurnal Health Sains, 7(4), 95-106. https://doi.org/10.46799/jhs.v7i4.2826

Vancouver

Muaziz AA, Utami HS, Oviyanti PN, Supriyadi S, Nugraha FR. Comparison of Agatston Score Calculation Between the Syngo.Via Automated Method and the Manual Method in Non-Contrast Cardiac CT. Jurnal Health Sains. 2026;7(4):95-106. doi:10.46799/jhs.v7i4.2826

BibTeX
@article{Muaziz2026,
  author = {Muaziz, Agil Abdul and Utami, Hernastiti Sedya and Oviyanti, Pradana Nur and Supriyadi, Supriyadi and Nugraha, Fathur Rahman},
  title = {Comparison of Agatston Score Calculation Between the Syngo.Via Automated Method and the Manual Method in Non-Contrast Cardiac CT},
  journal = {Jurnal Health Sains},
  year = {2026},
  volume = {7},
  number = {4},
  pages = {95--106},
  doi = {10.46799/jhs.v7i4.2826}
}
Kostenlos starten →