Combined 1-D and 2-D Electrical Resistivity Methods to Investigate Groundwater Contamination at a Landfill Site in Lokoja, North Central Nigeria
Engineering Research journal · 30.06.2026 · 6 (2) · 56-65
DOI: 10.46654/1zf5rv71 ↗Kurz gefasst
Fachartikel in der Zeitschrift Engineering Research journal, online erschienen am 30.06.2026. Verfasst von S. Mepaiyeda und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
An investigation was carried out to detect and delineate the extent of leachate contamination and intrusion into soil and groundwater resources around the Lokoja municipal landfill site, Nigeria. 1D and 2D electrical resistivity methods were applied to study the geoelectric properties of the subsurface to depth, determine the direction of pollutant flow relative to the groundwater flow and also distinguish between polluted and non-polluted zones with respect to groundwater contamination. Two vertical electrical sounding (VES) measurements and four 2D resistivity imagingusing the dipole-dipole array were taken along profiles across the landfill. The measured resistivity values were subjected to qualitative and quantitative interpretation. Two distinctive pollutants were observed around the landfill site- zones of contaminant leachate plumes mixed with decomposing waste, characterized by low resistivity values (< 65 ohm-m) to a depth of 5m and zones of high resistivity values (>340 ohm-m), identified as chemical compounds that are gaseous in nature to a depth of 11-13m. Interpretation of the 1D and 2D profiles showed that contamination of soil and groundwater resources have infiltrated to a depth of about 40m around the landfill area. The biological and chemical constituents of the pollutants need to be evaluated using a more detailed geochemical method. It is also recommended that continuous monitoring of the leachate migration should be carried out to minimize the environmental impact of the landfill on the soil and groundwater resources of the area.
Zitieren
APA
Mepaiyeda, S., & Ogbodo, D. (2026). Combined 1-D and 2-D Electrical Resistivity Methods to Investigate Groundwater Contamination at a Landfill Site in Lokoja, North Central Nigeria. Engineering Research journal, 6(2), 56-65. https://doi.org/10.46654/1zf5rv71
Vancouver
Mepaiyeda S, Ogbodo D. Combined 1-D and 2-D Electrical Resistivity Methods to Investigate Groundwater Contamination at a Landfill Site in Lokoja, North Central Nigeria. Engineering Research journal. 2026;6(2):56-65. doi:10.46654/1zf5rv71
BibTeX
@article{Mepaiyeda2026,
author = {Mepaiyeda, S. and Ogbodo, D.A.},
title = {Combined 1-D and 2-D Electrical Resistivity Methods to Investigate Groundwater Contamination at a Landfill Site in Lokoja, North Central Nigeria},
journal = {Engineering Research journal},
year = {2026},
volume = {6},
number = {2},
pages = {56--65},
doi = {10.46654/1zf5rv71}
}
EUVIMED