Comparative Optical Performance of Brain Tissue-Clearing Methods Combined with Immunostaining: A Systematic Review with Descriptive Quantitative Synthesis
Revista de Investigación e Innovación en Ciencias de la Salud · 20.03.2026 · 8 (2) · 1-27
DOI: 10.46634/riics.532 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Revista de Investigación e Innovación en Ciencias de la Salud, online erschienen am 20.03.2026. Verfasst von Jorge L. Anaya-González und 3 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Optical clearing has enabled three-dimensional visualization of brain tissue, but available methods differ in their ability to preserve morphology, achieve maximum effective imaging depth, and maintain fluorescent signal quality while minimizing unwanted background fluorescence.
Objective
To evaluate the optical and morphological performance of tissue-clearing protocols applied to immunostained brain structures through a systematic review with descriptive quantitative synthesis of studies published between 2014 and 2024.
Method
Experimental studies using human or rodent brain tissue combining optical clearing and immunostaining were identified through searches in Scopus and Web of Science following the PRISMA 2020 guidelines. Data were synthesized using descriptive statistics, group comparisons, non-parametric correlations, and exploratory regression analyses. Bibliometric network analyses were conducted using the software VOSviewer.
Results
Twelve experimental studies met the inclusion criteria. Organic solvent–based methods (iDISCO+, uDISCO) showed higher descriptive values of maximum effective imaging depth and lower levels of unwanted background fluorescence compared to hydrogel-based and hydrophilic approaches. Maximum effective imaging depth was significantly associated with reduced unwanted background fluorescence (ρ = –0.596; p = 0.041), while its association with fluorescent signal quality showed a non-significant positive trend (ρ = 0.570; p = 0.053).
Conclusion
Organic solvent–based clearing methods exhibited more favorable descriptive optical profiles, particularly with respect to imaging depth and background suppression. However, in the absence of statistically significant between-group differences, these findings should be interpreted as suggestive patterns rather than definitive evidence of superiority.
Zitieren
APA
Anaya-González, J. L., Velásquez-Calderón, C., MinietCastillo, A., & Chingal-Cando, J. J. (2026). Comparative Optical Performance of Brain Tissue-Clearing Methods Combined with Immunostaining: A Systematic Review with Descriptive Quantitative Synthesis. Revista de Investigación e Innovación en Ciencias de la Salud, 8(2), 1-27. https://doi.org/10.46634/riics.532
Vancouver
Anaya-González JL, Velásquez-Calderón C, MinietCastillo A, Chingal-Cando JJ. Comparative Optical Performance of Brain Tissue-Clearing Methods Combined with Immunostaining: A Systematic Review with Descriptive Quantitative Synthesis. Revista de Investigación e Innovación en Ciencias de la Salud. 2026;8(2):1-27. doi:10.46634/riics.532
BibTeX
@article{AnayaGonzlez2026,
author = {Anaya-González, Jorge L. and Velásquez-Calderón, Claudia and MinietCastillo, AdrianaEdit and Chingal-Cando, Juan José},
title = {Comparative Optical Performance of Brain Tissue-Clearing Methods Combined with Immunostaining: A Systematic Review with Descriptive Quantitative Synthesis},
journal = {Revista de Investigación e Innovación en Ciencias de la Salud},
year = {2026},
volume = {8},
number = {2},
pages = {1--27},
doi = {10.46634/riics.532}
}
EUVIMED