EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Self-Recovering Crosslinked Natural Rubber Sensors for Vascular Simulation in Wireless Electro-Syringe Injection

Korn Taksapattanakul, Panisara Wanmahamart

Proceedings of Engineering and Technology Innovation · 19.05.2026 · 33 · 132-147

DOI: 10.46604/peti.2026.16290 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of Engineering and Technology Innovation, online erschienen am 19.05.2026. Verfasst von Korn Taksapattanakul und 1 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Safe injection technique is recognized as a critical competency in medical training, yet access to realistic and affordable simulators remains limited. This study aims to develop a wireless electro-syringe system that incorporates a self-recovering crosslinked natural rubber sensor for vascular tissue response. The sensor is fabricated from natural rubber latex via controlled sulfur vulcanization, enabling autonomous structural recovery after repeated needle penetrations. A closed-circuit detection system delivers immediate feedback upon overpenetration, providing real-time performance guidance. Fourier transform infrared spectroscopy (FTIR) analysis confirms a reduction of carbon-carbon double bonds and the formation of carbon-sulfur crosslinks. Increasing vulcanization temperature and curing time enhances crosslinking density and improves mechanical performance and self-recovery properties. Diffusion analysis confirms Fickian behavior (n ≈ 0.5) with an activation energy of 31.244 kJ·mol-1. The elastic modulus gradually recovers after disruption, suggesting effective network reformation. Overall, this work provides a low-cost, reusable, and mechanically realistic solution for injection training.

Zitieren

APA

Taksapattanakul, K., & Wanmahamart, P. (2026). Self-Recovering Crosslinked Natural Rubber Sensors for Vascular Simulation in Wireless Electro-Syringe Injection. Proceedings of Engineering and Technology Innovation, 33, 132-147. https://doi.org/10.46604/peti.2026.16290

Vancouver

Taksapattanakul K, Wanmahamart P. Self-Recovering Crosslinked Natural Rubber Sensors for Vascular Simulation in Wireless Electro-Syringe Injection. Proceedings of Engineering and Technology Innovation. 2026;33:132-147. doi:10.46604/peti.2026.16290

BibTeX
@article{Taksapattanakul2026,
  author = {Taksapattanakul, Korn and Wanmahamart, Panisara},
  title = {Self-Recovering Crosslinked Natural Rubber Sensors for Vascular Simulation in Wireless Electro-Syringe Injection},
  journal = {Proceedings of Engineering and Technology Innovation},
  year = {2026},
  volume = {33},
  pages = {132--147},
  doi = {10.46604/peti.2026.16290}
}
Kostenlos starten →