Design and Development of an MQ-2 Sensor and Arduino Uno Gas Leak Detection System with Automatic Ventilation and Warning
Jurnal Penelitian · 24.07.2026 · 20 (1) · 71-82
DOI: 10.46491/jp.v20i1.2015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Jurnal Penelitian, online erschienen am 24.07.2026. Verfasst von Raul Gonjales Barus und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Gas leakage can create fire, explosion, and health hazards when it is not detected promptly. This study developed a laboratory-scale gas-leak detection prototype that integrates an MQ-2 metal-oxide sensor, Arduino Uno, 16×2 I2C LCD, audible and visual warnings, a relay, and an automatically activated exhaust fan. Prototype performance was evaluated through distance-based sensor-response tests, alarm-response-time trials, and time-resolved ventilation tests. The average MQ-2 output declined from 721.0 ADC counts at 5 cm to 150.0 ADC counts at 30 cm, indicating a consistent distance-dependent response under the reported test conditions. The warning chain activated in an average of 2.0 s. After fan activation, the average ADC response decreased by 46.7% after 30 s and 79.9% after 60 s relative to the initial reading. These percentages describe changes in relative sensor output, not calibrated gas concentration, because no certified reference-gas or parts-per-million calibration was performed. The prototype demonstrates the feasibility of combining local detection, warning logic, and automatic ventilation in one low-cost platform. It is intended as an educational and supervised proof of concept and should not be treated as a substitute for a certified combustible-gas detector or explosion-protected safety system.
Zitieren
APA
Barus, R. G., Fatmawati, U. D., Ariateja, D., Akbar, S. P., Roesdian, M. N. H., Rafif, G. R. R., & Kusuma, M. S. (2026). Design and Development of an MQ-2 Sensor and Arduino Uno Gas Leak Detection System with Automatic Ventilation and Warning. Jurnal Penelitian, 20(1), 71-82. https://doi.org/10.46491/jp.v20i1.2015
Vancouver
Barus RG, Fatmawati UD, Ariateja D, Akbar SP, Roesdian MNH, Rafif GRR, et al. Design and Development of an MQ-2 Sensor and Arduino Uno Gas Leak Detection System with Automatic Ventilation and Warning. Jurnal Penelitian. 2026;20(1):71-82. doi:10.46491/jp.v20i1.2015
BibTeX
@article{Barus2026,
author = {Barus, Raul Gonjales and Fatmawati, Uvi Desi and Ariateja, Dananjaya and Akbar, Satria Putra and Roesdian, Muhammad Nizar Helmy and Rafif, Grujs Ramadhan Raihan and Kusuma, Mulayasa Sparta},
title = {Design and Development of an MQ-2 Sensor and Arduino Uno Gas Leak Detection System with Automatic Ventilation and Warning},
journal = {Jurnal Penelitian},
year = {2026},
volume = {20},
number = {1},
pages = {71--82},
doi = {10.46491/jp.v20i1.2015}
}