EUVIMEDEUVIMED entdecken
Crossref

Incidence and outcomes of peripherally inserted central catheter associated thrombosis in a tertiary neonatal intensive care unit

Kamela Loo, Vidhi Shah, Naisha Chokshi, Indira Chandrasekar

Journal of Clinical Pediatrics and Neonatology · 2025

DOI: 10.46439/pediatrics.5.031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Pediatrics and Neonatology, 2025. Verfasst von Kamela Loo und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This 5-year retro-study determines the prevalence of thrombosis associated with PICC line insertion in infants hospitalized in NICU.

Background

Commonly placed central lines in neonatal intensive care units (NICU) include peripherally inserted central catheter (PICC), Umbilical venous lines (UVC) and Umbilical arterial lines (UAC). These central lines are accepted as the standard of care for nutrition and hemodynamic status monitoring. Neonates are known to be at risk for thromboembolism, particularly venous thromboembolism (VTE) related to central catheters. However, little is known about the true incidence of thrombosis and the requirement for therapy in this population Methods: With Institutional Review Board (IRB) approval, a retrospective review of PICC insertions performed at a Level IV Children's Hospital was conducted. The study period was from January 2016 to June 2020, during which, the patients who received lines were further investigated for thrombosis and phlebitis associated with PICC lines.

Results

2645 PICCs were placed on 2337 neonates over 5 year period. There were 194 documented thrombosis (7.3%). 75 PICCs were removed due to a diagnosis of phlebitis without using an ultrasound (2.8%). Lower limb PICCs were associated with a higher incidence of thrombosis (5.7%) compared to upper extremity PICCs (1.7%). 26% of Upper Extremity Thrombosis (UET) required low molecular weight heparin (LMWH) treatment vs 55% of Lower Extremity Thrombosis (LET). During the same period that 75 neonates (2.8%) had PICC lines removed due to phlebitis in the pre-ultrasound period.

Conclusion

In the current study, neonates with a lower extremity PICC was associated with higher rate of PICC line thrombosis compared to UE PICC and required anticoagulation therapy more often.

Zitieren

APA

Loo, K., Shah, V., Chokshi, N., & Chandrasekar, I. (2025). Incidence and outcomes of peripherally inserted central catheter associated thrombosis in a tertiary neonatal intensive care unit. Journal of Clinical Pediatrics and Neonatology. https://doi.org/10.46439/pediatrics.5.031

Vancouver

Loo K, Shah V, Chokshi N, Chandrasekar I. Incidence and outcomes of peripherally inserted central catheter associated thrombosis in a tertiary neonatal intensive care unit. Journal of Clinical Pediatrics and Neonatology. 2025. doi:10.46439/pediatrics.5.031

BibTeX
@article{Loo2025,
  author = {Loo, Kamela and Shah, Vidhi and Chokshi, Naisha and Chandrasekar, Indira},
  title = {Incidence and outcomes of peripherally inserted central catheter associated thrombosis in a tertiary neonatal intensive care unit},
  journal = {Journal of Clinical Pediatrics and Neonatology},
  year = {2025},
  doi = {10.46439/pediatrics.5.031}
}
Kostenlos starten →