EUVIMEDEUVIMED entdecken
Crossref

Comparison of urine sediment microscopy from two automated urine analyzers versus manual analysis

Bagnu Dundar, Hatice Nur Halipci Topsakal

Annals of Clinical and Analytical Medicine · 01.11.2026 · 17 (11) · 1148-1151

DOI: 10.4328/acam.50049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Clinical and Analytical Medicine, erschienen am 01.11.2026. Verfasst von Bagnu Dundar und 1 weiteren Autor:innen. Die Arbeit nennt 11 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Urine is considered a liquid biopsy sample, and its analysis consists of three main stages: physical, chemical, and microscopic sediment examination. These analyses can be performed manually or using automated urine analyzers. In this study, two different models of the same brand, DIRUI FUS-200 and DIRUI FUS-3000Plus, were evaluated by comparing their microscopic analysis results with manual examination findings, which were accepted as the reference method.

Methods

Parameters assessed included red blood cells (RBC), white blood cells (WBC), epithelial cells, hyaline casts, granular casts, and calcium oxalate crystals, which are among the most clinically relevant urine sediment elements. When statistical significance was detected, pairwise comparisons were conducted using the Mann–Whitney U test with Bonferroni correction. Binary parameters were evaluated using the McNemar test, and agreement between methods was assessed using Cohen’s kappa coefficient.

Results

No statistically significant differences were found among the three methods for WBC, RBC, and epithelial cell distributions (P > .05), consistent with previous reports on automated urine analyzers. In contrast, significant differences were observed among the methods for hyaline casts, granular casts, and calcium oxalate crystals (P < .05), indicating variability in the detection of rare or pathological sediment components.

Conclusion

The DIRUI FUS-200 and DIRUI FUS-3000Plus automated urine analyzers demonstrated comparable performance to manual microscopic examination for common urine sediment parameters such as WBC, RBC, and epithelial cells. Therefore, while automated urine analyzers provide reliable support for routine clinical urinalysis, manual microscopic examination remains essential for the confirmation of specific sediment components.

Zitieren

APA

Dundar, B., & Topsakal, H. N. H. (2026). Comparison of urine sediment microscopy from two automated urine analyzers versus manual analysis. Annals of Clinical and Analytical Medicine, 17(11), 1148-1151. https://doi.org/10.4328/acam.50049

Vancouver

Dundar B, Topsakal HNH. Comparison of urine sediment microscopy from two automated urine analyzers versus manual analysis. Annals of Clinical and Analytical Medicine. 2026;17(11):1148-1151. doi:10.4328/acam.50049

BibTeX
@article{Dundar2026,
  author = {Dundar, Bagnu and Topsakal, Hatice Nur Halipci},
  title = {Comparison of urine sediment microscopy from two automated urine analyzers versus manual analysis},
  journal = {Annals of Clinical and Analytical Medicine},
  year = {2026},
  volume = {17},
  number = {11},
  pages = {1148--1151},
  doi = {10.4328/acam.50049}
}
Kostenlos starten →