Intraoperative Coronary Artery Dissection during Pulmonary Valve Replacement after Repair of Tetralogy of Fallot
Japanese Journal of Cardiovascular Surgery · 15.05.2026 · 55 (3) · 99-102
DOI: 10.4326/jjcvs.55.99 ↗Kurz gefasst
Fachartikel in der Zeitschrift Japanese Journal of Cardiovascular Surgery, erschienen am 15.05.2026. Verfasst von Mikio Sugano und 5 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben.
Abstract (Originalsprache)
Surgical intervention was recommended for a 31-year-old woman with pulmonary regurgitation after intracardiac repair of Tetralogy of Fallot. Using a cardiopulmonary bypass with the heart beating, surgery was performed to replace the pulmonary valve. Transesophageal echocardiography revealed mildly decreased right ventricular systolic function after weaning from cardiopulmonary bypass. While careful inspection of the right coronary artery revealed no macroscopic abnormalities, during chest closure, the patient developed refractory ventricular fibrillation, requiring frequent defibrillation and reinitiation of cardiopulmonary bypass. The patient showed a marked decrease in right ventricular function, indicating severe coronary ischemia. Epicardial echocardiography was performed to assess the coronary arteries. Although no dissection was detected at the aortic root, including the cannulation site, dissection of the right coronary artery was confirmed. The patient was transferred to a hybrid operating room where coronary angiography and intravascular ultrasonography (IVUS) were performed, revealing extensive coronary artery dissection, with an initial entry near the right coronary artery ostium. The underlying cause was compression of the true lumen by the false lumen. Blood flow was significantly improved by creating a reentry channel to the distal part of the right coronary artery. The patient's sinus rhythm subsequently returned, and her hemodynamics stabilized, allowing successful weaning from cardiopulmonary bypass. No ischemic symptoms or ventricular arrhythmias have occurred since the surgery, and cardiac function is currently good. In this case, no direct intervention was performed on the coronary arteries. However, because the right coronary artery originated slightly to the left of the normal artery, the possibility that intraoperative mechanical stimulation may have caused the condition could not be ruled out. Although this is an extremely rare condition, prompt and accurate pathological evaluation and treatment led to a favorable outcome.
Zitieren
APA
Sugano, M., Kimura, Y., Matsumoto, R., Yamamoto, M., Kitaichi, T., & Hata, H. (2026). Intraoperative Coronary Artery Dissection during Pulmonary Valve Replacement after Repair of Tetralogy of Fallot. Japanese Journal of Cardiovascular Surgery, 55(3), 99-102. https://doi.org/10.4326/jjcvs.55.99
Vancouver
Sugano M, Kimura Y, Matsumoto R, Yamamoto M, Kitaichi T, Hata H. Intraoperative Coronary Artery Dissection during Pulmonary Valve Replacement after Repair of Tetralogy of Fallot. Japanese Journal of Cardiovascular Surgery. 2026;55(3):99-102. doi:10.4326/jjcvs.55.99
BibTeX
@article{Sugano2026,
author = {Sugano, Mikio and Kimura, Yuki and Matsumoto, Ryota and Yamamoto, Masaki and Kitaichi, Takashi and Hata, Hiroki},
title = {Intraoperative Coronary Artery Dissection during Pulmonary Valve Replacement after Repair of Tetralogy of Fallot},
journal = {Japanese Journal of Cardiovascular Surgery},
year = {2026},
volume = {55},
number = {3},
pages = {99--102},
doi = {10.4326/jjcvs.55.99}
}