EUVIMEDEUVIMED entdecken
Open Access

Evaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiography

E Sadik, C Gökmenoğlu, G Altun, C Kara

Medicina Oral Patología Oral y Cirugia Bucal · 2023

DOI: 10.4317/medoral.25501 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medicina Oral Patología Oral y Cirugia Bucal, 2023. Verfasst von E Sadik und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Radiology Faculty of Dentistry Ordu University 52200 Altinordu/Ordu - Turkey dttepe@hotmail.com. Hauptthemen laut MEDLINE: Peri-Implantitis, Dental Implants. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: To evaluate the accuracy of the diagnosis of peri-implant bone defects' severities in digital panoramic radiographs obtained at different tube voltage and/or tube current settings. MATERIAL AND METHODS: Two different sizes of peri-implant bone defects (type 1 and type 2) were prepared after the implants were inserted into 29 bovine rib blocks. Digital panoramic radiographs were obtained at eight different tube voltage and/or tube current settings for all rib blocks. Implant images were cropped separately. The average intensity value (AIV) of cropped images were analyzed using Adobe Photoshop CC software. The Kruskal-Wallis H test was used to compare AIVs. All cropped images were evaluated using a five-point Likert scale for the likelihood of a bone defect being absent or present. The weighted kappa values were calculated to compare observer agreement and ROC analysis was performed to determine the appropriate exposure parameters. RESULTS: The lowest AIV was obtained at 72 kV/6.3 mA (92.162±16.016), and the highest AIV was obtained at 60 kV/3.2 mA (179.050±13.823). The Kruskal-Wallis H test showed significant differences in the AIVs according to the exposure parameters (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Peri-ImplantitisDental ImplantsHumansAnimalsCattleRadiography, PanoramicRadiography, Dental, Digital

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Radiology Faculty of Dentistry Ordu University 52200 Altinordu/Ordu - Turkey dttepe@hotmail.com.

Zitieren

APA

Sadik, E., Gökmenoğlu, C., Altun, G., & Kara, C. (2023). Evaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiography. Medicina Oral Patología Oral y Cirugia Bucal. https://doi.org/10.4317/medoral.25501

Vancouver

Sadik E, Gökmenoğlu C, Altun G, Kara C. Evaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiography. Medicina Oral Patología Oral y Cirugia Bucal. 2023. doi:10.4317/medoral.25501

BibTeX
@article{Sadik2023,
  author = {Sadik, E and Gökmenoğlu, C and Altun, G and Kara, C},
  title = {Evaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiography},
  journal = {Medicina Oral Patología Oral y Cirugia Bucal},
  year = {2023},
  doi = {10.4317/medoral.25501}
}
Kostenlos starten →