EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access

Are flowable composite resins containing bioactive particles truly biocompatible?

Lara Rabelo Aragão, Julia Gonçalves Montenegro, Clarice Lioba de Araújo, José Vitor Mota Lemos, Dayrine Silveira de Paula, Sergio Lima Santiago, Suely Bezerra Dos Santos, Paulo Goberlânio de Barros Silva, Jiovanne Rabelo Neri

Journal of Clinical and Experimental Dentistry · 2026 · e729-e736

DOI: 10.4317/jced.63914 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Clinical and Experimental Dentistry, 2026. Verfasst von Lara Rabelo Aragão und 8 weiteren Autor:innen. Beteiligte Einrichtung: Master in Dental Sciences, University Christus, Fortaleza, Ceará, Brazil. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To evaluate the degree of conversion and biocompatibility of flowable composite resins containing bioactive particles using in vitro and in vivo models, respectively. Materials and Methods: The flowable composite resins Beautifil Flow Plus F00 (F00), Beautifil Flow Plus F03 (F03), and Filtek Supreme (FS) were tested. For the degree of conversion (DC) test, seven specimens were prepared for each group and analyzed using Raman spectroscopy. For biocompatibility (BC), seven specimens from each group were implanted into the dorsal subcutaneous tissue of 21 female Wistar rats, which were divided into three groups according to the experimental periods of 7, 14, and 28 days. After euthanasia, the dorsal tissues were surgically excised, fixed in formalin solution, and processed for histological analysis. The slides were evaluated blindly, and ten microscopic fields were randomly selected at 400× magnification. Statistical analysis for DC and BC was performed using the Kruskal-Wallis test, followed by Tukey's post hoc test for DC and Dunn's test for BC.

Results

For BC, F00 and F03 induced less inflammation and granulation tissue formation and promoted greater fibrosis than FS (p 0.05).

Conclusions

Flowable bioactive composite resins represent promising alternatives for dental practice, as they induce minimal tissue inflammation and exhibit high conversion rates.

Autor:innen und Institutionen

  • Master in Dental Sciences, University Christus, Fortaleza, Ceará, Brazil.
  • Graduate School of Dentistry, University Christus, Fortaleza, Ceará, Brazil.
  • Postgraduate Program in Dentistry, Faculty of Pharmacy, Dentistry and Nursing, Federal University of Ceará (UFC), Fortaleza, Ceará, Brazil.

Zitieren

APA

Aragão, L. R., Montenegro, J. G., de Araújo, C. L., Mota Lemos, J. V., de Paula, D. S., Santiago, S. L., Dos Santos, S. B., de Barros Silva, P. G., & Neri, J. R. (2026). Are flowable composite resins containing bioactive particles truly biocompatible?. Journal of Clinical and Experimental Dentistry, e729-e736. https://doi.org/10.4317/jced.63914

Vancouver

Aragão LR, Montenegro JG, de Araújo CL, Mota Lemos JV, de Paula DS, Santiago SL, et al. Are flowable composite resins containing bioactive particles truly biocompatible?. Journal of Clinical and Experimental Dentistry. 2026:e729-e736. doi:10.4317/jced.63914

BibTeX
@article{Arago2026,
  author = {Aragão, Lara Rabelo and Montenegro, Julia Gonçalves and de Araújo, Clarice Lioba and Mota Lemos, José Vitor and de Paula, Dayrine Silveira and Santiago, Sergio Lima and Dos Santos, Suely Bezerra and de Barros Silva, Paulo Goberlânio and Neri, Jiovanne Rabelo},
  title = {Are flowable composite resins containing bioactive particles truly biocompatible?},
  journal = {Journal of Clinical and Experimental Dentistry},
  year = {2026},
  pages = {e729--e736},
  doi = {10.4317/jced.63914}
}
Kostenlos starten →