EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access

Performance of Electronic Apex Locators, Root ZX3, NovApex N31, and Apex-S, in Irrigant Solutions of Varying Conductivity

Lucas Rodrigues de Araújo Estrela, Luciano Tavares Ngelo Cintra, Bruno Correa Azevedo, Giuliano Caixeta Serpa, Patrícia Correa Siqueira, Júlio Almeida Silva, Daniel Almeida Decurcio, Carlos Estrela

Journal of Clinical and Experimental Dentistry · 2026 · e881-e888

DOI: 10.4317/jced.63279 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Clinical and Experimental Dentistry, 2026. Verfasst von Lucas Rodrigues de Araújo Estrela und 7 weiteren Autor:innen. Beteiligte Einrichtung: DDS, MSc. Universidade Estadual Paulista - UNESP, Department of Endodontics, Araçatuba, SP, Brazil. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The success of root canal treatment depends on precise control of the working length (WL), as it directly influences periapical healing and long-term prognosis. Optimal outcomes are achieved when obturation ends short of the radiographic apex, which requires accurate WL determination. This study evaluated the performance of electronic apex locators (EALs) in irrigant solutions with different electrical conductivities. Materials and Methods: Twenty human mandibular central incisors were assessed using Root ZX3®, NovApex N31®, and Apex-S®. Standardized reference lengths were established from the incisal edge to the root apex with a digital micrometer (DM). A size 15 K-file attached to each EAL was inserted into the canals until the devices indicated the apical foramen. The silicone stoppers were adjusted to the incisal edge, and the files were removed to measure the length with the DM. The differences between the lengths measured by the EALs and the actual WL were calculated. Statistical analysis was performed using the Friedman test followed by Tukey's post-hoc test, and the Kruskal-Wallis test with the Student-Newman-Keuls post-hoc test. The significance level was set at = 0.05.

Results

Root ZX3® showed the highest accuracy (p 0.05). When deionized water was used, both NovApex N31® and Apex-S® demonstrated minimal interference, whereas significant differences were observed with 2.5% NaOCl and Triton®.

Conclusions

Root ZX3® demonstrated consistent accuracy across all irrigating solutions. NovApex N31® and Apex-S® performed similarly in deionized water but showed differences when compared with 2.5% NaOCl and Triton®.

Autor:innen und Institutionen

  • DDS, MSc. Universidade Estadual Paulista - UNESP, Department of Endodontics, Araçatuba, SP, Brazil.
  • Universidade Estadual Paulista - UNESP, Department of Endodontics, Araçatuba, SP, Brazil.
  • DDS, MSc. IB Bender Postdoctoral Endodontic Program, Albert Einstein Medical Center, Philadelphia, Pennsylvania, USA.
  • DDS, MSc, PhD. Professor of Endodontics, Department of Stomatology Sciences, Federal University of Goiás, Goiânia, Brazil.

Zitieren

APA

de Araújo Estrela, L. R., Ngelo Cintra, L. T., Azevedo, B. C., Serpa, G. C., Siqueira, P. C., Silva, J. A., Decurcio, D. A., & Estrela, C. (2026). Performance of Electronic Apex Locators, Root ZX3, NovApex N31, and Apex-S, in Irrigant Solutions of Varying Conductivity. Journal of Clinical and Experimental Dentistry, e881-e888. https://doi.org/10.4317/jced.63279

Vancouver

de Araújo Estrela LR, Ngelo Cintra LT, Azevedo BC, Serpa GC, Siqueira PC, Silva JA, et al. Performance of Electronic Apex Locators, Root ZX3, NovApex N31, and Apex-S, in Irrigant Solutions of Varying Conductivity. Journal of Clinical and Experimental Dentistry. 2026:e881-e888. doi:10.4317/jced.63279

BibTeX
@article{deArajoEstrela2026,
  author = {de Araújo Estrela, Lucas Rodrigues and Ngelo Cintra, Luciano Tavares and Azevedo, Bruno Correa and Serpa, Giuliano Caixeta and Siqueira, Patrícia Correa and Silva, Júlio Almeida and Decurcio, Daniel Almeida and Estrela, Carlos},
  title = {Performance of Electronic Apex Locators, Root ZX3, NovApex N31, and Apex-S, in Irrigant Solutions of Varying Conductivity},
  journal = {Journal of Clinical and Experimental Dentistry},
  year = {2026},
  pages = {e881--e888},
  doi = {10.4317/jced.63279}
}
Kostenlos starten →