Inter- and intra-observer reliability of injury diagnosis for peri-knee fractures: A comparison between two- and three-dimensional CT imaging
Malawi Medical Journal · 2025
DOI: 10.4314/mmj.v36i5.6 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Malawi Medical Journal, 2025. Verfasst von Hui Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710061, China. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Tomography, X-Ray Computed, Tibial Fractures, Femoral Fractures. Die Arbeit wurde bisher 3-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Natural Science Foundation of Shaanxi Province.
Abstract (Originalsprache)
Objective
This study aimed to assess whether three-dimensional (3D) CT imaging improves the inter- and intra-observer reliability of peri-knee fracture classifications, compared to two-dimensional (2D) CT imaging.
Methods
A retrospective analysis was conducted on 23 patients with peri-knee fractures, using both 2D and 3D-CT scans. Three radiologists classified distal femur, patella, and tibial plateau fractures according to Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) and Schatzker systems. Reliability was measured using Cohen’s kappa, with evaluations conducted at two separate intervals to assess intra- and inter-observer consistency.ResultsThe intra-observer reliability for 2D-CT was substantial for distal femur (κ = 0.737, IQR 0.615–0.788) and tibial plateau (κ = 0.732, IQR 0.615–0.819) fractures, improving slightly with 3D-CT (κ = 0.775, IQR 0.658–0.869; κ = 0.768, IQR 0.628–0.882 respectively). Patella fracture classification showed almost perfect reliability (κ = 0.823, IQR 0.707–0.882) with 2D-CT, further improving with 3D-CT (κ = 0.865, IQR 0.764–0.951). However, inter-observer reliability showed no significant improvement with the addition of 3D-CT across all fracture types.
Conclusion
While 3D-CT marginally enhances intra-observer reliability for peri-knee fractures, the difference in inter-observer reliability compared to 2D-CT was not statistically significant.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Imaging, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710061, China.
- Radiology Department, Mzuzu Central Hospital, Mzuzu, Malawi.
- Department of Surgery Intensive Care Unit, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710061, China.
Förderung
- Natural Science Foundation of Shaanxi Province
Zitieren
APA
Zhang, H., Manda, P., Nyirenda, B. K., Kondowe, B., Wang, W., & Shang, J. (2025). Inter- and intra-observer reliability of injury diagnosis for peri-knee fractures: A comparison between two- and three-dimensional CT imaging. Malawi Medical Journal. https://doi.org/10.4314/mmj.v36i5.6
Vancouver
Zhang H, Manda P, Nyirenda BK, Kondowe B, Wang W, Shang J. Inter- and intra-observer reliability of injury diagnosis for peri-knee fractures: A comparison between two- and three-dimensional CT imaging. Malawi Medical Journal. 2025. doi:10.4314/mmj.v36i5.6
BibTeX
@article{Zhang2025,
author = {Zhang, Hui and Manda, Patrick and Nyirenda, Brave Kadoko and Kondowe, Blessed and Wang, Wenjing and Shang, Jin},
title = {Inter- and intra-observer reliability of injury diagnosis for peri-knee fractures: A comparison between two- and three-dimensional CT imaging},