EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Determination of Spent Water Filtration Multimedia by Extent of Treatment and Filter Rejuvenation Performance

E F Sodiya, O S Odunuga, A Olawore, V O Oki, E Bamgbade

Journal of Chemical Society of Nigeria · 28.04.2026 · 51 (2) · 240-262

DOI: 10.4314/jcsn.v51i2.4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chemical Society of Nigeria, online erschienen am 28.04.2026. Verfasst von E F Sodiya und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Mountain Top University water treatment plant is a commercial venture for internal revenue generation that uses multi-media filtration. Quality challenges has been occurring in the treatment process as a result of non monitored performance of the filter media. Expiration of the filter media had been based on a period and not on the actual number of times used. The recharge of filtration media is a function of the volume of operation engaged by the media. The degree of depreciation in media retention shall thus determine the discharged time of spent media. This work quantified the number of contaminants retained on the filter media per a period of time as a measure of the filtration efficiency and life span of the media. The data obtained from the filter media clean-up (back wash operation (BO) of the media) over a scheduled period shall be used as a tool to determine the rate of contaminants retention. Samples were taken weekly before backwash operations (BBO) and after backwash operations (ABO) from inlet and outlet of each of the three sequentially connected filtration cylinders containing akdolite with sand, carbon with sand and resin with sand respectively. Both Inlet (inflow into filtration cylinder) and Outlet (outflow from the filtration cylinder samples were taken for a span of 11 weeks. The sampling was taken while the system was on treatment mode just before embarking on back wash operations (BBO) and immediately after back wash operation (ABO) when the system have been reversed to treatment mode. Physicochemical analysis such as Turbidity, Colour, and Total Solids (TS), were carried out on the samples. Turbidity, Iron content and Ca/Mg Hardness were determined spectrophotometerically with appropriate reagents. While gravimetric methods of analysis were used to determine, Total dissolved solids (TDS) and Total suspended solids (TSS). The extent of treatment and filter rejuvenating evaluation were evaluated. The parallel difference of about 1mg/L between the graph of BBO and ABO in Figure 3 across the weeks from the combinations of filteration cylinders containing multimedia of Akdolite and sand by which Turbidity was measured. The same occurs in Figure 2 where colour was monitored. Figure 3 also reveals fluctuations in total hardness from the filter rejuvenating evaluation in which 1mg/L to about 15mg/L on an average was retained on the filter bed This as indicated an imperfect exchange of ions on the charged resins. It implies weakness in the ion exchange capacity of the resin. The filter rejuvenating evaluation from the sand components of the multimedia in all the three filtration cylinders as indicated an insignificant contaminants retention at both operations of both BBO and ABO. The ABO contaminants were of minimal difference to that of BBO which indicated that the media is spent. However, turbidity and colour FRE remained constant (∆ ≈ 1 unit) about the same input, showing those media are still active. Thus, exhaustion is specific parameter‑, not uniform across the multimedia components. Filter Rejuvenation Evaluation (FRE) gaps between the graphs closing to near‑zero for TSS, TDS, hardness and iron is an indication of exhausted filter layers. The wider in the graph indicates high efficiency of the media. Due to the difference in the functional modes of the multimedia components, therefore the value or range of filter rejuvenating evaluation to determine a spent media cannot parallelly applied to all multimedia components. In multimedia filtration cylinder, media of different functions loaded in the same chamber are not spent at the same time.

Zitieren

APA

Sodiya, E. F., Odunuga, O. S., Olawore, A., Oki, V. O., & Bamgbade, E. (2026). Determination of Spent Water Filtration Multimedia by Extent of Treatment and Filter Rejuvenation Performance. Journal of Chemical Society of Nigeria, 51(2), 240-262. https://doi.org/10.4314/jcsn.v51i2.4

Vancouver

Sodiya EF, Odunuga OS, Olawore A, Oki VO, Bamgbade E. Determination of Spent Water Filtration Multimedia by Extent of Treatment and Filter Rejuvenation Performance. Journal of Chemical Society of Nigeria. 2026;51(2):240-262. doi:10.4314/jcsn.v51i2.4

BibTeX
@article{Sodiya2026,
  author = {Sodiya, E F and Odunuga, O S and Olawore, A and Oki, V O and Bamgbade, E},
  title = {Determination of Spent Water Filtration Multimedia by Extent of Treatment and Filter Rejuvenation Performance},
  journal = {Journal of Chemical Society of Nigeria},
  year = {2026},
  volume = {51},
  number = {2},
  pages = {240--262},
  doi = {10.4314/jcsn.v51i2.4}
}
Kostenlos starten →