Existing Condition and Operational Performance of Madaba Water Supply System in Ruvuma Region, Tanzania

B. Chacha, L. Swilla, C. Nditi

Journal of Applied Sciences and Environmental Management · 2026 · 30 (6) · 1961-1967

DOI: 10.4314/jasem.v30i6.27 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Sciences and Environmental Management, 2026. Verfasst von B. Chacha und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rural water supply systems in Tanzania frequently experience service unreliability due to ageing infrastructure, inadequate storage capacity, pump inefficiency, and high-water losses. This study assessed the existing condition and operational performance of the Madaba Water Supply System in Ruvuma Region, Tanzania. Using various standard methods, including field inspection, operational record review, and performance indicator assessment, the study evaluated source reliability, storage adequacy, pipe network condition, production–demand balance, pump performance, system reliability, downtime, and non-revenue water. The system depended on one perennial source and three seasonal sources, with seasonal sources declining substantially during the dry season. Existing storage facilities had a total capacity of 550 m³, with a mean tank capacity of 110.00 ± 65.19 m³, equivalent to only 0.33 days of maximum daily demand. The distribution network extended 45.2 km, with a mean pipe-class length of 11.30 ± 3.32 km, and 54% of the network consisted of pipes with diameters of 90 mm or less. Average daily water production was 945 m³/day compared with an estimated demand of 1,109 m³/day, indicating a production deficit. Pump efficiency was 58.4%, average monthly downtime was 112 hours, system reliability was 64.7%, and non-revenue water was 38.4%. The study concluded that the system is structurally functional but operationally weak. Storage expansion, rehabilitation of undersized and deteriorated pipes, pump optimisation, leakage control, and routine performance monitoring are recommended to improve service reliability. The study contributes a practical indicator-based framework for diagnosing operational weaknesses and supporting evidence-based improvement of rural water supply systems.

Zitieren

APA

Chacha, B., Swilla, L., & Nditi, C. (2026). Existing Condition and Operational Performance of Madaba Water Supply System in Ruvuma Region, Tanzania. Journal of Applied Sciences and Environmental Management, 30(6), 1961-1967. https://doi.org/10.4314/jasem.v30i6.27

Vancouver

Chacha B, Swilla L, Nditi C. Existing Condition and Operational Performance of Madaba Water Supply System in Ruvuma Region, Tanzania. Journal of Applied Sciences and Environmental Management. 2026;30(6):1961-1967. doi:10.4314/jasem.v30i6.27

BibTeX
@article{Chacha2026,
  author = {Chacha, B. and Swilla, L. and Nditi, C.},
  title = {Existing Condition and Operational Performance of Madaba Water Supply System in Ruvuma Region, Tanzania},
  journal = {Journal of Applied Sciences and Environmental Management},
  year = {2026},
  volume = {30},
  number = {6},
  pages = {1961--1967},
  doi = {10.4314/jasem.v30i6.27}
}