EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Foetal weight estimation, at term, using a multivariate algorithm of maternal characteristics, has an accuracy similar to that of ultrasonography.

Akeem A Iyiola, Peter N Ebeigbe, Uduak A Ochei, Agabi J Oyeribhor, Godwin E Okungbowa

Ghana Medical Journal · 2025

DOI: 10.4314/gmj.v58i4.8 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Ghana Medical Journal, 2025. Verfasst von Akeem A Iyiola und 4 weiteren Autor:innen. Beteiligte Einrichtung: Federal Medical Centre, Asaba, Delta State, Nigeria. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Fetal Weight, Algorithms. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the accuracy of foetal weight estimation using a multivariate algorithm based on maternal characteristics and pregnancy-specific factors to that of ultrasound.

Design

A cross-sectional hospital-based study.

Setting

Antenatal Clinics and Antenatal Labour wards of the Department of Obstetrics & Gynaecology, Federal Medical Centre, Asaba, Nigeria.

Participants

A total of 92 pregnant women were admitted for labour, elective caesarean section or elective induction of labour at 37 weeks to 41 weeks and 3 days.Main outcome measures: Mean of absolute error, mean of absolute percentage error and proportion of estimated weight within 10% of actual birth weight.

Results

Between April and August 2021, 92 participants were included. An equation based on maternal characteristics was derived. Ultrasound weight estimation was done using Hadlock’s 4 formula. Both methods positively correlated with actual birth weight, and their accuracy did not differ significantly. Overall accuracy within 10% of actual birth weight was higher for ultrasonography than multivariate algorithm 71.7% and 65.2%, respectively (χ2=0.286, p=0.60). The mean absolute percentage error was smaller for ultrasound (7.98±4.74%) than clinical formula (9.11±6.76%) p=0.11. The mean absolute error was 265.57±145.67g for ultrasonography and 304.32±203.29g for the multivariate model, with no statistical difference (p=0.09).

Conclusion

The multivariate algorithm based on maternal characteristics and pregnancy-specific factors was equally accurate as ultrasonography for foetal weight estimation at term.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, PrenatalFetal WeightAlgorithmsHumansFemalePregnancyCross-Sectional StudiesAdultBirth WeightNigeriaYoung AdultGestational Age

Stichwörter der Autor:innen

Maternal characteristicsmultivariate algorithmtermultrasound

Autor:innen und Institutionen

  • Federal Medical Centre, Asaba, Delta State, Nigeria.
  • Delta State University, Abraka, Nigeria and Federal Medical Centre, Asaba, Delta State, Nigeria.
  • Department of Radiography, School of Basic Medical Sciences, College of Medical Sciences, University of Benin, Benin City, Nigeria.

Zitieren

APA

Iyiola, A. A., Ebeigbe, P. N., Ochei, U. A., Oyeribhor, A. J., & Okungbowa, G. E. (2025). Foetal weight estimation, at term, using a multivariate algorithm of maternal characteristics, has an accuracy similar to that of ultrasonography. Ghana Medical Journal. https://doi.org/10.4314/gmj.v58i4.8

Vancouver

Iyiola AA, Ebeigbe PN, Ochei UA, Oyeribhor AJ, Okungbowa GE. Foetal weight estimation, at term, using a multivariate algorithm of maternal characteristics, has an accuracy similar to that of ultrasonography. Ghana Medical Journal. 2025. doi:10.4314/gmj.v58i4.8

BibTeX
@article{Iyiola2025,
  author = {Iyiola, Akeem A and Ebeigbe, Peter N and Ochei, Uduak A and Oyeribhor, Agabi J and Okungbowa, Godwin E},
  title = {Foetal weight estimation, at term, using a multivariate algorithm of maternal characteristics, has an accuracy similar to that of ultrasonography},
  journal = {Ghana Medical Journal},
  year = {2025},
  doi = {10.4314/gmj.v58i4.8}
}
Kostenlos starten →