Evaluation of the Efficacy of Ultraviolet-C Apparatus in Preventing the Transmission of Hospital Acquired Infections, Jimma University, Southwest Ethiopia

Yibeltal Siraneh, Bikela Alemu, Lidet Tadele, Zeleke Mekonnen, Rahel Tamrat, Edris Hasanpoor, Samira Raoofi

Ethiopian Medical Journal · 2025 · 64 (1)

DOI: 10.4314/emj.v64i1.26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ethiopian Medical Journal, 2025. Verfasst von Yibeltal Siraneh und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ultraviolet light at a wavelength of 254 nm (UV-C) is recognized for its bactericidal, sporicidal, fungicidal, and virucidal properties. Defining the exact position, dose, and time of disinfection for a UV-C device in clinical settings is crucial to ensure its proper functioning and to achieve the anticipated disinfection efficacy. However, the efficacy of a newly designed UV-C device produced in Ethiopia has not yet been evaluated. Therefore, this study aimed to determine the antimicrobial efficacy of the newly designed device.

Methods

A laboratory-based experimental study was conducted starting from July 01 to 03, 2021, using different types of bacteria responsible for hospital-acquired infections, specifically those available from the American Type Culture Collection (ATCC). The bacteria tested included Pseudomonas aeruginosa ATCC 27853, Escherichia coli ATCC 25922, and Staphylococcus aureus ATCC 25923. Overnight cultures of microorganisms were harvested in sterile 0.85% saline, and the optical densities were adjusted to 0.5 McFarland standards (ÿ1.5 × 10^8 CFU/ml). These cultures were then exposed to light radiated from the new UV-C devices (same models with same UV intensity), with varying distances (in meters) and exposure times (in minutes), while control groups were maintained without exposure.

Results

The UV-C device demonstrated efficacy at 25 minutes (min) at distances of 1, 3, and 6.5 meters in the exposure group, yielding different logarithmic (log) reduction values. Notably, all three vegetative bacteria were eliminated at a 1 m distance during the 25 min exposure time, and the direct net reduction rates confirmed the log10-reduction status.Conclusion and Recommendation: The efficacy of the UV-C device increased as the distance to the UV-C light decreased and the exposure time increased. Therefore, the promotion and use of this device for disinfecting rooms and objects, while adhering to precautionary safety measures, are recommended.

Zitieren

APA

Siraneh, Y., Alemu, B., Tadele, L., Mekonnen, Z., Tamrat, R., Hasanpoor, E., & Raoofi, S. (2025). Evaluation of the Efficacy of Ultraviolet-C Apparatus in Preventing the Transmission of Hospital Acquired Infections, Jimma University, Southwest Ethiopia. Ethiopian Medical Journal, 64(1). https://doi.org/10.4314/emj.v64i1.26

Vancouver

Siraneh Y, Alemu B, Tadele L, Mekonnen Z, Tamrat R, Hasanpoor E, et al. Evaluation of the Efficacy of Ultraviolet-C Apparatus in Preventing the Transmission of Hospital Acquired Infections, Jimma University, Southwest Ethiopia. Ethiopian Medical Journal. 2025;64(1). doi:10.4314/emj.v64i1.26

BibTeX
@article{Siraneh2025,
  author = {Siraneh, Yibeltal and Alemu, Bikela and Tadele, Lidet and Mekonnen, Zeleke and Tamrat, Rahel and Hasanpoor, Edris and Raoofi, Samira},
  title = {Evaluation of the Efficacy of Ultraviolet-C Apparatus in Preventing the Transmission of Hospital Acquired Infections, Jimma University, Southwest Ethiopia},
  journal = {Ethiopian Medical Journal},
  year = {2025},
  volume = {64},
  number = {1},
  doi = {10.4314/emj.v64i1.26}
}
Kostenlos starten →