EUVIMEDEUVIMED entdecken
Crossref

A new method for determining isoniazid drug by flow injection analysis with a merging zone technique

Ahmed Saleh Farhood, Rahmah Hashim Abdullah, Amal Saadoon Majeed, Nahlah Salman Saddam, Dakhil Nassir Taha

Bulletin of the Chemical Society of Ethiopia · 22.01.2025 · 39 (4) · 601-613

DOI: 10.4314/bcse.v39i4.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bulletin of the Chemical Society of Ethiopia, online erschienen am 22.01.2025. Verfasst von Ahmed Saleh Farhood und 4 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigated the designing of a simple and rapid flow injection (FI) system and the determination of Isoniazid in a prepared aqueous solution. The principle of the method depended on the indirect reaction of the isoniazid drug with copper(II)-neocuproine (Cu(II)-NCPR) complex after acidifying the aqueous medium. The yellow-orange and charge transfer complex had maximum absorption at 455 nm. The optimum conditions of the FIA were studied. The calibration graph of isoniazid was constructed with a linear range of 0.10 to 10.00 mg/L, and a linearity (r2) value of 0.9988. The detection and quantification limits were 0.073 and 0.221 mg/L, respectively. The molar absorptivity (ε) was 56.68×104 L/mol.cm and Sandell's sensitivity was 0.84 ×10-3 µg/cm. The manufactured local valve was characterized by inexpensive, easily running, high repeatability (n = 6) at an RSD of 2.18%, and the dead volume was zero. The dispersion coefficient values were 1.91, and 1.53 for both concentrations of 0.60, and 4.00 mg/L, respectively. The sampling rate of the analysis for the FIA system was 63.00 samples per hour. The proposed analytical flow injection method was successfully applied to standard aqueous solutions and tablets of isoniazid. Bull. Chem. Soc. Ethiop. 2025, 39(4), 601-613. DOI: https://dx.doi.org/10.4314/bcse.v39i4.1

Zitieren

APA

Farhood, A. S., Abdullah, R. H., Majeed, A. S., Saddam, N. S., & Taha, D. N. (2025). A new method for determining isoniazid drug by flow injection analysis with a merging zone technique. Bulletin of the Chemical Society of Ethiopia, 39(4), 601-613. https://doi.org/10.4314/bcse.v39i4.1

Vancouver

Farhood AS, Abdullah RH, Majeed AS, Saddam NS, Taha DN. A new method for determining isoniazid drug by flow injection analysis with a merging zone technique. Bulletin of the Chemical Society of Ethiopia. 2025;39(4):601-613. doi:10.4314/bcse.v39i4.1

BibTeX
@article{Farhood2025,
  author = {Farhood, Ahmed Saleh and Abdullah, Rahmah Hashim and Majeed, Amal Saadoon and Saddam, Nahlah Salman and Taha, Dakhil Nassir},
  title = {A new method for determining isoniazid drug by flow injection analysis with a merging zone technique},
  journal = {Bulletin of the Chemical Society of Ethiopia},
  year = {2025},
  volume = {39},
  number = {4},
  pages = {601--613},
  doi = {10.4314/bcse.v39i4.1}
}
Kostenlos starten →