EUVIMEDEUVIMED entdecken
MetaanalyseSystematische ÜbersichtOpen Access

Meta-analysis of the effect of static computer-assisted dental implantation on the accuracy of dental implantation in esthetic area

Zhongping Yin, Huifang Kuang, Li Li, Xi Si

African Health Sciences · 15.07.2025 · 25 (2) · 343-353

DOI: 10.4314/ahs.v25i2.40 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift African Health Sciences, online erschienen am 15.07.2025. Verfasst von Zhongping Yin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center of Stomatology, The Second Affiliated Hospital of Hainan Medical University, Haikou, China. Hauptthemen laut MEDLINE: Dental Implantation, Dental Implantation, Endosseous, Dental Implants, Esthetics, Dental. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This system evaluates the effect of static navigation systems on accuracy (platform, apical and angular deviation) in clinical studies of implant surgery in the anterior aesthetic zone to inform clinical decision-making. Methodology: Retrieve Pubmed, Embase, Cochrane library databases, as well as randomized controlled trials (RCT) and controlled clinical trials (CCT) comparing dynamic navigation and static guidance published by the US Clinical Trial Registry before May 1, 2023. The outcome indicators included in the study include measuring the deviation between the preoperative design of the implant and the actual site at the top, apex, and angle. The calculation of meta-analysis was performed using Review Manager version 5.2 software.

Results

1134 articles were screened and retrieved, and finally 4 studies were included for quantitative analysis. Meta analysis results showed that the two groups had lower depth angle deviation (WMD=-0.30, 95%CI: (0.24, 1.78), P=0.01) at the top (WMD=0.14, 95% CI: (-0.26, 0.55), P=0.49) and root tip (WMD=0.25, 95%CI: (-0.34, 0.84), P=0.41) compared to the static guide plate group, and the difference was statistically significant.

Conclusion

The static guide plate provides a small implant placement error, which is comparable to the error obtained using dynamic navigation systems, but dynamic navigation exhibits a smaller angle deviation. Keywords: Static guide plate; Dynamic navigation; Anterior teeth aesthetic district; Implant; Meta-analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantationDental Implantation, EndosseousDental ImplantsEsthetics, DentalSurgery, Computer-AssistedHumans

Stichwörter der Autor:innen

Anterior teeth aesthetic districtDynamic navigationImplantMeta-analysisStatic guide plate

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Center of Stomatology, The Second Affiliated Hospital of Hainan Medical University, Haikou, China.
  • Department of Stomatology, First Affiliated Hospital of Hainan Medical University, Haikou, China.
  • Department of Nephrology, Geriatric Hospital of Hainan, Haikou, China.
  • School of Stomatology, Hainan Medical University, Haikou, China.

Zitieren

APA

Yin, Z., Kuang, H., Li, L., & Si, X. (2025). Meta-analysis of the effect of static computer-assisted dental implantation on the accuracy of dental implantation in esthetic area. African Health Sciences, 25(2), 343-353. https://doi.org/10.4314/ahs.v25i2.40

Vancouver

Yin Z, Kuang H, Li L, Si X. Meta-analysis of the effect of static computer-assisted dental implantation on the accuracy of dental implantation in esthetic area. African Health Sciences. 2025;25(2):343-353. doi:10.4314/ahs.v25i2.40

BibTeX
@article{Yin2025,
  author = {Yin, Zhongping and Kuang, Huifang and Li, Li and Si, Xi},
  title = {Meta-analysis of the effect of static computer-assisted dental implantation on the accuracy of dental implantation in esthetic area},
  journal = {African Health Sciences},
  year = {2025},
  volume = {25},
  number = {2},
  pages = {343--353},
  doi = {10.4314/ahs.v25i2.40}
}
Kostenlos starten →