EUVIMEDEUVIMED entdecken
Open Access

Analysis of factors related to tip malposition of peripherally inserted central catheter and its spontaneous correction rate in neonates

Lizhu Chen, Kunying Zhuang, Meili Zhang

African Health Sciences · 2025

DOI: 10.4314/ahs.v25i2.15 ↗

Kurz gefasst

Fachartikel in der Zeitschrift African Health Sciences, 2025. Verfasst von Lizhu Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neonatel Intensive Care Unit, Quanzhou Woman's and Children's Hospital, Quanzhou 362000, China. Hauptthemen laut MEDLINE: Catheterization, Peripheral, Catheterization, Central Venous, Central Venous Catheters. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To analyze the factors associated with tip malposition and spontaneous correction rate of peripherally inserted central catheter (PICC) in newborns.

Methods

Clinical data of 1604 newborns who underwent PICC placement in our neonatal surgery department from January 2018 to January 2023 were retrospectively analyzed. They were divided into malposition group (n=104) and normal group (n=1500) according to the occurrence of tip malposition. The relevant clinical data of newborns were extracted from the hospital information system. The occurrence of PICC tip malposition and spontaneous correction were recorded. Logistic regression analysis was used to identify risk factors for PICC tip malposition in newborns.

Results

The incidence of PICC malposition was 6.48%. There were significant differences in gestational age, birth weight, lesion location, catheter direction and venous placement between the two groups (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheterization, PeripheralCatheterization, Central VenousCentral Venous CathetersHumansInfant, NewbornRetrospective StudiesFemaleMaleRisk FactorsGestational AgeIncidence

Stichwörter der Autor:innen

Peripherally inserted central catheterneonatal carespontaneous correctiontip malposition

Autor:innen und Institutionen

  • Department of Neonatel Intensive Care Unit, Quanzhou Woman's and Children's Hospital, Quanzhou 362000, China.

Zitieren

APA

Chen, L., Zhuang, K., & Zhang, M. (2025). Analysis of factors related to tip malposition of peripherally inserted central catheter and its spontaneous correction rate in neonates. African Health Sciences. https://doi.org/10.4314/ahs.v25i2.15

Vancouver

Chen L, Zhuang K, Zhang M. Analysis of factors related to tip malposition of peripherally inserted central catheter and its spontaneous correction rate in neonates. African Health Sciences. 2025. doi:10.4314/ahs.v25i2.15

BibTeX
@article{Chen2025,
  author = {Chen, Lizhu and Zhuang, Kunying and Zhang, Meili},
  title = {Analysis of factors related to tip malposition of peripherally inserted central catheter and its spontaneous correction rate in neonates},
  journal = {African Health Sciences},
  year = {2025},
  doi = {10.4314/ahs.v25i2.15}
}
Kostenlos starten →