EUVIMEDEUVIMED entdecken
Open Access

Diagnostic value of FNA, ultrasound elastography and CEUS in thyroid carcinoma

Lei Zhao, Lin Zhao, Hui Chen, Rongfei Huang, Qian Wei, Jian Liu

African Health Sciences · 2024

DOI: 10.4314/ahs.v24i3.23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift African Health Sciences, 2024. Verfasst von Lei Zhao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasonic Medicine, Chengdu Medical College, Clinical Medical College and The First Affiliated Hospital of Chengdu Medical College, Ch…. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Thyroid Neoplasms. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To investigate the role of fine needle aspiration cytology (FNA), sonoelastography and contrast-enhanced ultrasound (CEUS) in the diagnosis of thyroid carcinoma. Methodology: A total of 150 patients with suspected thyroid cancer admitted to our hospital from January 2019 to December 2021 were selected and divided into group A, group B and group C according to random number table, with 50 cases in each group. FNA was used in group A, ultrasound elastography was used in group B, and CEUS was used in group C. Pathological diagnosis was performed in all patients, and the diagnostic sensitivity, specificity, and accuracy were compared among the three groups.

Results

The diagnostic sensitivity, specificity and accuracy of FNA in group A were 90.91%, 70.59% and 84.00%, respectively; the diagnostic sensitivity, specificity and accuracy of ultrasound elastography in group B were 94.12%, 81.25% and 90.00%, respectively; the diagnostic sensitivity, specificity and accuracy of CEUS in group C were 88.57%, 73.33% and 84.00%, respectively; the three groups were compared (P > 0.05).

Conclusion

All three diagnostic techniques had a relatively high sensitivity and accuracy in the diagnosis of thyroid carcinoma. Ultrasound elastography had the highest sensitivity and specificity among the three techniques, while FNA and CEUS had similar diagnostic performance. Keywords: Fine needle aspiration cytology; ultrasound elastography; contrast-enhanced ultrasound; thyroid cancer; diagnostic efficacy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesThyroid NeoplasmsHumansFemaleMaleSensitivity and SpecificityBiopsy, Fine-NeedleMiddle AgedAdultUltrasonographyContrast MediaAged

Stichwörter der Autor:innen

Fine needle aspiration cytologycontrast-enhanced ultrasounddiagnostic efficacythyroid cancerultrasound elastography

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Ultrasonic Medicine, Chengdu Medical College, Clinical Medical College and The First Affiliated Hospital of Chengdu Medical College, Chengdu, China.
  • Department of Pathology, Chengdu Medical College, Clinical Medical College and The First Affiliated Hospital of Chengdu Medical College, Chengdu, China.

Zitieren

APA

Zhao, L., Zhao, L., Chen, H., Huang, R., Wei, Q., & Liu, J. (2024). Diagnostic value of FNA, ultrasound elastography and CEUS in thyroid carcinoma. African Health Sciences. https://doi.org/10.4314/ahs.v24i3.23

Vancouver

Zhao L, Zhao L, Chen H, Huang R, Wei Q, Liu J. Diagnostic value of FNA, ultrasound elastography and CEUS in thyroid carcinoma. African Health Sciences. 2024. doi:10.4314/ahs.v24i3.23

BibTeX
@article{Zhao2024,
  author = {Zhao, Lei and Zhao, Lin and Chen, Hui and Huang, Rongfei and Wei, Qian and Liu, Jian},
  title = {Diagnostic value of FNA, ultrasound elastography and CEUS in thyroid carcinoma},
  journal = {African Health Sciences},
  year = {2024},
  doi = {10.4314/ahs.v24i3.23}
}
Kostenlos starten →