EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Evaluation of Insulation Characteristics of Submarine Cables in Offshore Wind Farm by Excessive Tension

Seung-won Lee, Jin-wook Choe, Ik-su Kwon, Dong-eun Kim, Hae Jong Kim

Journal of Korean Institute of Electrical and Electronic Materials Engineers · 01.05.2024 · 37 (3) · 286-291

DOI: 10.4313/jkem.2024.37.3.7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Korean Institute of Electrical and Electronic Materials Engineers, erschienen am 01.05.2024. Verfasst von Seung-won Lee und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Research on aged insulation of cables by stress is constantly being considered for reliable and stable power transmission of offshore wind farms. This study aimed to evaluate the insulation characteristic of aged XLPE (cross-linked polyethylene) insulation for application of offshore wind farms. In this study, The XLPE insulation of cable was set as various mechanical strains. The XLPE insulation is exposed to the mechanical stress below yield strain of 5%, 10%, and 20%. Aged samples were tested by using the method of AC BDV (alternative current breakdown voltage), tensile strength, elongation, and SEM (scanning electron microscope) to obtain insulation characteristics. The experimental results show that the dielectric breakdown of the sample with a strain 20% was 50% lower than the unaged sample; thereby, demonstrating that the mechanical strain that occurred in the submarine cables can weaken the insulation characteristics. Therefore, mechanical strain should be monitored when laying and operating submarine cables for offshore wind farms.

Zitieren

APA

Lee, S., Choe, J., Kwon, I., Kim, D., & Kim, H. J. (2024). Evaluation of Insulation Characteristics of Submarine Cables in Offshore Wind Farm by Excessive Tension. Journal of Korean Institute of Electrical and Electronic Materials Engineers, 37(3), 286-291. https://doi.org/10.4313/jkem.2024.37.3.7

Vancouver

Lee S, Choe J, Kwon I, Kim D, Kim HJ. Evaluation of Insulation Characteristics of Submarine Cables in Offshore Wind Farm by Excessive Tension. Journal of Korean Institute of Electrical and Electronic Materials Engineers. 2024;37(3):286-291. doi:10.4313/jkem.2024.37.3.7

BibTeX
@article{Lee2024,
  author = {Lee, Seung-won and Choe, Jin-wook and Kwon, Ik-su and Kim, Dong-eun and Kim, Hae Jong},
  title = {Evaluation of Insulation Characteristics of Submarine Cables in Offshore Wind Farm by Excessive Tension},
  journal = {Journal of Korean Institute of Electrical and Electronic Materials Engineers},
  year = {2024},
  volume = {37},
  number = {3},
  pages = {286--291},
  doi = {10.4313/jkem.2024.37.3.7}
}
Kostenlos starten →