Thoracoscopic Intrathoracic Double-Flap Technique for EGJC
JSLS : Journal of the Society of Laparoscopic & Robotic Surgeons · 2026
DOI: 10.4293/jsls.2026.00035 ↗Kurz gefasst
Fachartikel in der Zeitschrift JSLS : Journal of the Society of Laparoscopic & Robotic Surgeons, 2026. Verfasst von Takeshi Ono und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Nakagami Hospital, Okinawa, Japan. Hauptthemen laut MEDLINE: Esophageal Neoplasms, Esophagectomy, Esophagogastric Junction, Gastrectomy. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Valvuloplastic esophagogastrostomy using the double-flap technique (DFT) after proximal gastrectomy and lower esophagectomy for esophagogastric junction cancer (EGJC) is effective for reflux prevention and has a low anastomotic leakage rate, making it suitable for mediastinal reconstruction. When the transhiatal approach becomes difficult, intrathoracic reconstruction provides a safer option. Although several reports have described robot-assisted intrathoracic DFT, thoracoscopic intrathoracic DFT has been reported only in isolated cases, and its technical feasibility and reproducibility have not been evaluated as a case series.
Methods
We present a consecutive six-patient case series of thoracoscopic intrathoracic DFT following laparoscopic proximal gastrectomy and lower esophagectomy. After preparation of a seromuscular flap, the remnant stomach was elevated into the thoracic cavity without torsion. The posterior esophageal wall was fixed to the flap using a single barbed suture placed in a continuous fashion with four bites, followed by 90° rotation of the esophagogastric axis to bring the anastomotic site into direct view. A full-circumference hand-sewn esophagogastrostomy using single-knot sutures was then completed, and the flap was closed.
Results
All procedures were completed thoracoscopically without conversion. The median reconstruction time was 78 minutes, and no anastomosis-related complications were observed.
Conclusions
This case series demonstrates the technical feasibility and reproducibility of thoracoscopic intrathoracic DFT for mediastinal esophagogastrostomy. Standardized exposure using posterior fixation and 90° rotation allows stable intracavitary suturing and supports the safe application of this valve-forming reconstruction in the thoracic cavity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, Nakagami Hospital, Okinawa, Japan.
Zitieren
APA
Ono, T., Tamaki, Y., Ohta, T., Hayashi, K., Orokawa, T., & Sunagawa, H. (2026). Thoracoscopic Intrathoracic Double-Flap Technique for EGJC. JSLS : Journal of the Society of Laparoscopic & Robotic Surgeons. https://doi.org/10.4293/jsls.2026.00035
Vancouver
Ono T, Tamaki Y, Ohta T, Hayashi K, Orokawa T, Sunagawa H. Thoracoscopic Intrathoracic Double-Flap Technique for EGJC. JSLS : Journal of the Society of Laparoscopic & Robotic Surgeons. 2026. doi:10.4293/jsls.2026.00035
BibTeX
@article{Ono2026,
author = {Ono, Takeshi and Tamaki, Yorito and Ohta, Takano and Hayashi, Keigo and Orokawa, Tomofumi and Sunagawa, Hiroki},
title = {Thoracoscopic Intrathoracic Double-Flap Technique for EGJC},
journal = {JSLS : Journal of the Society of Laparoscopic & Robotic Surgeons},
year = {2026},
doi = {10.4293/jsls.2026.00035}
}
EUVIMED