EUVIMEDEUVIMED entdecken
Open Access

Clinical Performance and Patient Satisfaction of Hybrid Contact Lenses in Patients with Keratoconus

Aydogdy Serdarov iD, Banu Bozkurt iD, Yalçın Karaküçük iD, Süleyman Okudan iD

Turkish Journal of Ophthalmology · 2023

DOI: 10.4274/tjo.galenos.2022.43077 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Turkish Journal of Ophthalmology, 2023. Verfasst von Aydogdy Serdarov und 3 weiteren Autor:innen. Beteiligte Einrichtung: Selçuk Univeristy Faculty of Medicine, Department of Ophthalmology, Konya, Türkiye. Hauptthemen laut MEDLINE: Keratoconus, Contact Lenses. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of the study was to evaluate the fitting process, clinical performance, and patient satisfaction of hybrid contact lenses (HCL) in patients with keratoconus (KC). Materials and Methods: Sixty-eight KC patients (35 female, 33 male) who were prescribed HCL were included in the study. Corneal topographic parameters, best corrected visual acuity (BCVA) with eyeglasses, the number of HCL trials, prescribed HCL base curve (BC), and visual acuity with HCL were recorded from hospital records. A contact lens satisfaction survey was sent to the patients via email or WhatsApp and the data was statistically analyzed using IBM SPSS Statistics version 22.0.

Results

The study included 110 eyes of 68 patients with a mean age of 27.34±8 years (range: 12-48 years). According to the Amsler-Krumeich classification, 35.5% of the eyes were stage 1, 50.9% were stage 2, and 13.5% were stage 3 or 4. Mean K1, K2, and Kmean values were 7.14±0.50 mm (range 5.72-8.30 mm), 6.63±0.49 mm (range 5.07-7.84 mm), and 6.89±0.48 mm (range 5.39-8.06 mm), respectively. The average number of lens trials was 1.59±0.82 (range 1-4). The mean BC of the prescribed HCL was 6.84±0.50 mm (range 5.60-8.00 mm). BCVA with glasses was 0.36±0.2 (range 0.05-0.8), and 0.80±0.14 (range 0.3-1.0) with HCL (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KeratoconusContact LensesHumansFemaleMaleYoung AdultAdultPatient SatisfactionCorneal Topography

Stichwörter der Autor:innen

Keratoconuscontact lens satisfactionhybrid contact lenssurvey

Autor:innen und Institutionen

  • Selçuk Univeristy Faculty of Medicine, Department of Ophthalmology, Konya, Türkiye.

ORCID-Profile: Aydogdy Serdarov, Banu Bozkurt, Yalçın Karaküçük, Süleyman Okudan

Zitieren

APA

Serdarov, A., Bozkurt, B., Karaküçük, Y., & Okudan, S. (2023). Clinical Performance and Patient Satisfaction of Hybrid Contact Lenses in Patients with Keratoconus. Turkish Journal of Ophthalmology. https://doi.org/10.4274/tjo.galenos.2022.43077

Vancouver

Serdarov A, Bozkurt B, Karaküçük Y, Okudan S. Clinical Performance and Patient Satisfaction of Hybrid Contact Lenses in Patients with Keratoconus. Turkish Journal of Ophthalmology. 2023. doi:10.4274/tjo.galenos.2022.43077

BibTeX
@article{Serdarov2023,
  author = {Serdarov, Aydogdy and Bozkurt, Banu and Karaküçük, Yalçın and Okudan, Süleyman},
  title = {Clinical Performance and Patient Satisfaction of Hybrid Contact Lenses in Patients with Keratoconus},
  journal = {Turkish Journal of Ophthalmology},
  year = {2023},
  doi = {10.4274/tjo.galenos.2022.43077}
}
Kostenlos starten →