EUVIMEDEUVIMED entdecken
Crossref

Lower Extremity Validation of a Human Body Model for High Rate Axial Loading in the Underbody Blast Environment

Zachary S Hostetler, Juliette Caffrey, Jazmine Aira, F Scott Gayzik

Stapp Car Crash Journal · 2023

DOI: 10.4271/2022-22-0004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stapp Car Crash Journal, 2023. Verfasst von Zachary S Hostetler und 3 weiteren Autor:innen. Beteiligte Einrichtung: Wake Forest School of Medicine- Biomedical Engineering. Hauptthemen laut MEDLINE: Human Body, Lower Extremity. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

While the use of Human Body Models (HBMs) in the underbody blast (UBB) environment has increased and shown positive results, the potential of these models has not been fully explored. Obtaining accurate kinematic and kinetic response are necessary to better understand the injury mechanisms for military safety applications. The objective of this study was to validate the Global Human Body Models Consortium (GHBMC) M50 lower extremity using a combined objective rating scheme in vertical and horizontal high-rate axial loading. The model’s lower extremity biomechanical response was compared to Post Mortem Human Subjects (PMHS) subjects for vertically and horizontally-applied high rate axial loading. Two distinct experimental setups were used for model validation, comprising a total of 33 distinct end points for validation. A combined Correlation and Analysis (CORA) score that incorporates CORA, time-to-peak (TTP) and peak magnitude of the experimental signals and ISO TS 18571 was used to evaluate the model response. For the horizontal impacts, the combined CORA scores were 0.80, 0.84, and 0.81 for compression, force, and strain respectively. For the vertical impacts combined CORA scores for the knee Z force, compression and heel Z displacement ranged from 0.70-0.81, 0.87-0.91, and 0.82-0.99 respectively. The GHBMC lower extremity model showed good agreement with PMHS experimental data in the horizontal and vertical loading environment in 33 unique tests. The accuracy is demonstrated by using the ISO TS 18571 standard and a combined CORA score that takes into consideration the peak and time to peak of the signal. The results of this study show that GHBMC v 6.0 HBM lower extremity can be used for kinetic and kinematic predictions in the UBB environment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Human BodyLower ExtremityHumansCadaverWeight-BearingHeel

Stichwörter der Autor:innen

Injury RiskBlastHuman Body ModelingLower ExtremityMilitary Safety

Autor:innen und Institutionen

  • Wake Forest School of Medicine- Biomedical Engineering.

Zitieren

APA

Hostetler, Z. S., Caffrey, J., Aira, J., & Gayzik, F. S. (2023). Lower Extremity Validation of a Human Body Model for High Rate Axial Loading in the Underbody Blast Environment. Stapp Car Crash Journal. https://doi.org/10.4271/2022-22-0004

Vancouver

Hostetler ZS, Caffrey J, Aira J, Gayzik FS. Lower Extremity Validation of a Human Body Model for High Rate Axial Loading in the Underbody Blast Environment. Stapp Car Crash Journal. 2023. doi:10.4271/2022-22-0004

BibTeX
@article{Hostetler2023,
  author = {Hostetler, Zachary S and Caffrey, Juliette and Aira, Jazmine and Gayzik, F Scott},
  title = {Lower Extremity Validation of a Human Body Model for High Rate Axial Loading in the Underbody Blast Environment},
  journal = {Stapp Car Crash Journal},
  year = {2023},
  doi = {10.4271/2022-22-0004}
}
Kostenlos starten →