Photon-counting detector computed tomography for the assessment of coronary stents and in-stent restenosis
EuroIntervention · 2025-10 · 21 (19) · e1137-e1146
DOI: 10.4244/eij-d-25-00257 ↗Kurz gefasst
Fachartikel in der Zeitschrift EuroIntervention, 2025-10. Verfasst von Doosup Shin und 22 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, St Francis Hospital & Heart Center, Roslyn, NY, USA. Hauptthemen laut MEDLINE: Coronary Restenosis, Stents, Computed Tomography Angiography. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: Photon-counting detector computed tomography (PCD-CT) offers enhanced spatial resolution and reduced blooming artefacts, potentially improving the evaluation of stented coronary vessels. AIMS: This study aimed to assess the diagnostic performance of dual-source PCD-CT in detecting obstructive in-stent restenosis (ISR). METHODS: We identified consecutive patients with prior coronary stent implantation who underwent clinically indicated coronary computed tomography angiography (CCTA) with PCD-CT and subsequent invasive coronary angiography within 90 days between 2023 and 2024. Obstructive ISR (≥50% diameter stenosis) was determined by visual assessment of CCTA and invasive quantitative coronary angiography (QCA) in a blinded fashion. The diagnostic performance of CCTA for ISR was compared with that of QCA. RESULTS: A total of 283 stented lesions from 171 patients were included. Of these, only 3 lesions (1.1%) were deemed indeterminate by PCD-CT. Using invasive QCA as the reference standard, PCD-CT demonstrated a lesion-level sensitivity of 80.0%, specificity of 90.4%, positive predictive value (PPV) of 58.2%, negative predictive value (NPV) of 96.4%, and an overall diagnostic accuracy of 88.9% for detecting obstructive ISR. In a subgroup analysis according to the stent diameter (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Cardiology, St Francis Hospital & Heart Center, Roslyn, NY, USA.
- Department of Cardiology, Radboud University Medical Center, Nijmegen, the Netherlands.
- Division of Cardiovascular Imaging, St Francis Hospital & Heart Center, Roslyn, NY, USA.
- New York Institute of Technology, Old Westbury, NY, USA.
- Department of Cardiology, National University Heart Centre, Singapore.
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium.
Zitieren
APA
Shin, D., Volleberg, R. H. J. A., Parikh, R., Yang Koo, C. C., Malik, S., Cannata, M., Caron, E., Ciftcikal, Y., Sakai, K., Cao, J. J., Chen, L., Sosa, F., Weber, J., Khan, J. M., Cohen, D. J., Moses, J. W., van Royen, N., Collet, C., Shlofmitz, R. A., …, & Ali, Z. A. (2025). Photon-counting detector computed tomography for the assessment of coronary stents and in-stent restenosis. EuroIntervention, 21(19), e1137-e1146. https://doi.org/10.4244/eij-d-25-00257
Vancouver
Shin D, Volleberg RHJA, Parikh R, Yang Koo CC, Malik S, Cannata M, et al. Photon-counting detector computed tomography for the assessment of coronary stents and in-stent restenosis. EuroIntervention. 2025;21(19):e1137-e1146. doi:10.4244/eij-d-25-00257
BibTeX
@article{Shin2025,
author = {Shin, Doosup and Volleberg, Rick H J A and Parikh, Roosha and Yang Koo, Christopher Chieh and Malik, Sarah and Cannata, Matthew and Caron, Emma and Ciftcikal, Yasemin and Sakai, Koshiro and Cao, J Jane and Chen, Lu and Sosa, Fernando and Weber, Jonathan and Khan, Jaffar M and Cohen, David J and Moses, Jeffrey W and van Royen, Niels and Collet, Carlos and Shlofmitz, Richard A and Shlofmitz, Evan and Jeremias, Allen and Khalique, Omar K and Ali, Ziad A},
title = {Photon-counting detector computed tomography for the assessment of coronary stents and in-stent restenosis},
journal = {EuroIntervention},
year = {2025},
volume = {21},
number = {19},
pages = {e1137--e1146},
doi = {10.4244/eij-d-25-00257}
}
EUVIMED