EUVIMEDEUVIMED entdecken
Open Access

Prediction of fractional flow reserve using intravascular ultrasound

Munenori Okubo, Masanori Kawasaki, Hiroyuki Yagami, Toru Tanigaki, Yoshiaki Kawase, Hitoshi Matsuo, Takahiko Suzuki

EuroIntervention · 2024

DOI: 10.4244/eij-d-24-00010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift EuroIntervention, 2024. Verfasst von Munenori Okubo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Gifu Heart Center, Gifu, Japan. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Ultrasonography, Interventional, Coronary Stenosis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: In order to identify coronary lesions that cause myocardial ischaemia and require revascularisation, fractional flow reserve (FFR) is widely recommended. Recently, a method of estimating the FFR using morphological features measured by an imaging device was developed. However, all the previously developed methods are conducted offline, and such analysis takes approximately 10 minutes. AIMS: The aim of this present study was to develop an online measurement of the FFR using an intravascular ultrasound (IVUS) quantitative method (IQ-FFR). METHODS: This prospective, single-centre study included coronary lesions that met the following criteria: (1) presence of at least one stenosis (25-99%); (2) both IVUS and FFR measurement performed just before and after stent implantation, with the wire-derived FFR measured with a standard method; and (3) acquisition of clear images throughout the entire coronary branch. RESULTS: We developed an IVUS analysis system that automatically measures the cross-sectional area every 0.5 mm, and we calculated the IQ-FFR. In the prediction study, we calculated the IQ-FFR on the assumption that one stent of arbitrary length and diameter was implanted. After stent implantation, the wire-derived FFR was measured and compared with the calculated IQ-FFR. We compared 270 coronary lesions with stenosis rates of 32-99%. IQ-FFR measurements were strongly correlated with the wire-derived FFR (r=0.896). In the prediction study, the clinical accuracy of predicting whether the FFR would be greater or less than 0.80 after stent implantation was 87.5%. CONCLUSIONS: The IQ-FFR is a promising method to identify coronary lesions requiring revascularisation and to predict the FFR after stent implantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractional Flow Reserve, MyocardialUltrasonography, InterventionalCoronary StenosisHumansFemaleMaleMiddle AgedAgedProspective StudiesCoronary AngiographyPercutaneous Coronary InterventionStentsPredictive Value of TestsCoronary VesselsCoronary Artery Disease

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Gifu Heart Center, Gifu, Japan.
  • Department of Cardiology, Deep Sound Laboratory, Shizuoka, Japan.
  • Department of Cardiovascular Medicine, Toyohashi Heart Center, Aichi, Japan.

Zitieren

APA

Okubo, M., Kawasaki, M., Yagami, H., Tanigaki, T., Kawase, Y., Matsuo, H., & Suzuki, T. (2024). Prediction of fractional flow reserve using intravascular ultrasound. EuroIntervention. https://doi.org/10.4244/eij-d-24-00010

Vancouver

Okubo M, Kawasaki M, Yagami H, Tanigaki T, Kawase Y, Matsuo H, et al. Prediction of fractional flow reserve using intravascular ultrasound. EuroIntervention. 2024. doi:10.4244/eij-d-24-00010

BibTeX
@article{Okubo2024,
  author = {Okubo, Munenori and Kawasaki, Masanori and Yagami, Hiroyuki and Tanigaki, Toru and Kawase, Yoshiaki and Matsuo, Hitoshi and Suzuki, Takahiko},
  title = {Prediction of fractional flow reserve using intravascular ultrasound},
  journal = {EuroIntervention},
  year = {2024},
  doi = {10.4244/eij-d-24-00010}
}
Kostenlos starten →