Long-term cardiac computed tomography follow-up after left atrial appendage occlusion
EuroIntervention · 2024
DOI: 10.4244/eij-d-23-00802 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift EuroIntervention, 2024. Verfasst von Lasse Hubertus Tiroke und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark. Hauptthemen laut MEDLINE: Atrial Appendage, Atrial Fibrillation, Septal Occluder Device, Tomography, X-Ray Computed. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: Left atrial appendage occlusion (LAAO) is performed increasingly, but long-term follow-up imaging data are lacking. AIMS: The aim of this study was to evaluate the safety and durability of the Amplatzer Amulet device >4 years after LAAO. METHODS: This was a prospective observational cohort study including 52 patients implanted with the Amplatzer Amulet device at Aarhus University Hospital, Denmark. A >4-year follow-up cardiac computed tomography (CT) scan after LAAO was performed and compared with the results from the 2-month and 12-month scans. The primary outcome was left atrial appendage (LAA) sealing based on distal LAA contrast patency and peridevice leakage (PDL), stratified into complete occlusion (grade 0 [G0]) and grade 1-3 leakage (G1-3), respectively. Secondary outcomes were low- and high-grade hypoattenuated thickening (HAT), device-related thrombosis (DRT) and device durability. RESULTS: The median (interquartile range [IQR]) follow-up time from LAAO to the latest CT scan was 5.8 years (4.5; 6.3). At 2-month (n=52), 12-month (n=27) and >4-year CT follow-ups (n=52), rates of both complete occlusion (33%, 37%, 35%) and G2 leaks (52%, 52%, 48%) remained stable. Rates of G1 leaks varied (14%, 4%, 6%) and G3 leaks rose (2%, 7%, 12%) from earliest to latest follow-up. The median left atrial (LA) volume increased from 127 mL (96; 176) to 144 mL (108; 182) and 147 mL (107; 193). No DRT was found. The structural device integrity was preserved. CONCLUSIONS: This study indicates a stable LAA sealing status throughout the follow-up period, emphasising the importance of the procedural result in avoiding PDL. Few patients displayed PDL progression, which might partly be related to LA remodelling with increasing volume. The long-term device durability appears excellent. Larger studies are warranted to confirm these findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark.
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
Zitieren
APA
Tiroke, L. H., Kramer, A., Poulsen, M. W., Jensen, C. D., Jensen, J. M., Nørgaard, B. L., Korsholm, K., & Nielsen-Kudsk, J. E. (2024). Long-term cardiac computed tomography follow-up after left atrial appendage occlusion. EuroIntervention. https://doi.org/10.4244/eij-d-23-00802
Vancouver
Tiroke LH, Kramer A, Poulsen MW, Jensen CD, Jensen JM, Nørgaard BL, et al. Long-term cardiac computed tomography follow-up after left atrial appendage occlusion. EuroIntervention. 2024. doi:10.4244/eij-d-23-00802
BibTeX
@article{Tiroke2024,
author = {Tiroke, Lasse Hubertus and Kramer, Anders and Poulsen, Mette Wørmer and Jensen, Caroline Damsgaard and Jensen, Jesper Møller and Nørgaard, Bjarne Linde and Korsholm, Kasper and Nielsen-Kudsk, Jens Erik},
title = {Long-term cardiac computed tomography follow-up after left atrial appendage occlusion},
journal = {EuroIntervention},
year = {2024},
doi = {10.4244/eij-d-23-00802}
}
EUVIMED