Fachartikel in der Zeitschrift EuroIntervention, 2023. Verfasst von Mariama Akodad und 12 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Heart Valve Innovation, St Paul's Hospital, University of British Columbia, Vancouver, BC, Canada. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Heart Valve Prosthesis, Aortic Valve Stenosis. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Coronary obstruction and access are concerns in patients undergoing redo transcatheter aortic valve implantation (TAVI). AIMS: We sought to assess the neoskirt height, leaflet overhang, leaflet deflection,and transcatheter heart valve (THV) expansion and performance, at 2 different implant depths, of the SAPIEN 3 Ultra (S3U) within the ACURATE neo2 (ACn2) THV. METHODS: An in vitro study was performed with a 23 mm S3U deployed within a small (S) ACn2 and a 26 mm S3U deployed within a medium (M) and a large (L) ACn2. The S3U outflow was positioned at the top of the ACn2 crown (low implant) and at the base of the commissural post of the ACn2 (high implant). Testing was performed under physiological conditions as per ISO-5840-3 standard. RESULTS: The neoskirt height was shorter when the S3U outflow was positioned at a low implantation depth (S: 9.6 mm, M: 12.2 mm, L: 13.8 mm vs S: 15.2 mm, M: 15.1 mm, L: 17.8 mm ACn2 for high implants). Hydrodynamic performance was acceptable for all configurations. Leaflet overhang was 2 mm for all configurations. The S3U was underexpanded for all configurations, and the achieved area was 77.9%-92.9% of the expected nominal area. CONCLUSIONS: Redo TAVI with an S3U within an ACn2 has favourable hydrodynamics and moderate leaflet overhang. Importantly, the design of the ACn2 results in a neoskirt that is not deflected all the way to the outer dimensions of the THV, hence creating a space that facilitates coronary flow and access.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementHeart Valve ProsthesisAortic Valve StenosisHumansAortic ValveCathetersProsthesis DesignTreatment Outcome

Autor:innen und Institutionen

  • Centre for Heart Valve Innovation, St Paul's Hospital, University of British Columbia, Vancouver, BC, Canada.
  • Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, BC, Canada.
  • Cardiovascular Translational Laboratory, Centre for Heart Lung Innovation & Providence Research, Vancouver, BC, Canada.
  • Institut Cardiovasculaire Paris Sud, Hôpital privé Jacques-Cartier, Ramsay Santé, Massy, France.
  • Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
  • Department of Cardiology, National University of Ireland, Galway, (NUIG), Galway, Ireland.

Zitieren

APA

Akodad, M., Meier, D., Sellers, S., de Backer, O., Mylotte, D., Landes, U., Frawley, C., Lynch, L., Tang, G. H. L., Sondergaard, L., Wood, D. A., Webb, J. G., & Sathananthan, J. (2023). A bench study of balloon-expandable valves for the treatment of self-expanding valve failure. EuroIntervention. https://doi.org/10.4244/eij-d-22-00769

Vancouver

Akodad M, Meier D, Sellers S, de Backer O, Mylotte D, Landes U, et al. A bench study of balloon-expandable valves for the treatment of self-expanding valve failure. EuroIntervention. 2023. doi:10.4244/eij-d-22-00769

BibTeX
@article{Akodad2023,
  author = {Akodad, Mariama and Meier, David and Sellers, Stephanie and de Backer, Ole and Mylotte, Darren and Landes, Uri and Frawley, Chris and Lynch, Lisa and Tang, Gilbert H L and Sondergaard, Lars and Wood, David A and Webb, John G and Sathananthan, Janarthanan},
  title = {A bench study of balloon-expandable valves for the treatment of self-expanding valve failure},
  journal = {EuroIntervention},
  year = {2023},
  doi = {10.4244/eij-d-22-00769}
}
Kostenlos starten →