Sutureless portal vein reconstruction in porcine orthotopic liver transplantation using a microvascular coupler: A randomized study with artificial intelligence-assisted histopathology
World Journal of Gastrointestinal Surgery · 27.08.2026 · 18 (8)
DOI: 10.4240/wjgs.120360 ↗Kurz gefasst
Fachartikel in der Zeitschrift World Journal of Gastrointestinal Surgery, online erschienen am 27.08.2026. Verfasst von Jun-Jie Li und 9 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND Portal vein reconstruction is a critical step in liver transplantation. Hand-sutured anastomosis is time-consuming and may predispose to malalignment, needle-hole bleeding, and stenosis. A sutureless, mechanically coupled anastomotic principle that minimizes mechanical trauma and foreign body reaction could improve healing. AIM To compare a microvascular anastomotic coupler (embodying the sutureless principle) with conventional hand-suturing for portal vein reconstruction in a translational porcine orthotopic liver transplantation model. METHODS Forty male pigs (weighing 60-66 kg) were randomized (1:1) to coupler or hand-sutured portal vein anastomosis. The primary endpoint was anastomosis time. Secondary endpoints included 12-week patency, portal venous velocity (Doppler), liver biochemistry, and detailed histopathological analysis of the anastomotic site. Histological evaluation was performed using an artificial intelligence-assisted workflow (ChatGPT-4.0 with vision) for pre-segmentation and provisional quantification, with all outputs independently reviewed and corrected by two blinded observers. Final analyses were conducted using the observer-verified values. RESULTS Coupler use halved anastomosis time (12.4 ± 2.2 minutes vs 24.5 ± 3.8 minutes, P < 0.001). Twelve-week patency was comparable (100% vs 95%, P = 1.000). Portal venous velocity remained stable and was consistently higher in the coupler group (immediate: 20.5 ± 3.1 cm/second vs 18.3 ± 2.6 cm/second, P = 0.020; 12-week: 22.9 ± 3.4 cm/second vs 20.8 ± 2.8 cm/second, P = 0.040). Liver function tests showed no significant between-group differences. Histology revealed significantly fewer inflammatory cells (macrophages, lymphocytes, and plasma cells) and a smaller necrotic area in the coupler group (e.g. , macrophages: 5.3 ± 1.1 vs 8.6 ± 1.5 per high power field, P < 0.001), along with lower inflammation and tissue disorganization scores (both P < 0.001). CONCLUSION In a porcine liver transplantation model, the microvascular anastomotic coupler enables faster portal vein reconstruction while maintaining excellent patency, favorable hemodynamics, and superior histologic healing. These findings support its translational potential for clinical use.
Zitieren
APA
Li, J., Yang, J., Xie, Y., Shang, J., Li, J., Chen, C., Liu, L., Zhang, Z., Pan, B., & Jiang, W. (2026). Sutureless portal vein reconstruction in porcine orthotopic liver transplantation using a microvascular coupler: A randomized study with artificial intelligence-assisted histopathology. World Journal of Gastrointestinal Surgery, 18(8). https://doi.org/10.4240/wjgs.120360
Vancouver
Li J, Yang J, Xie Y, Shang J, Li J, Chen C, et al. Sutureless portal vein reconstruction in porcine orthotopic liver transplantation using a microvascular coupler: A randomized study with artificial intelligence-assisted histopathology. World Journal of Gastrointestinal Surgery. 2026;18(8). doi:10.4240/wjgs.120360
BibTeX
@article{Li2026,
author = {Li, Jun-Jie and Yang, Jian and Xie, Yan and Shang, Jia-Ming and Li, Jiang and Chen, Chi-Yi and Liu, Li-Na and Zhang, Zhong-Ying and Pan, Bing-Hui and Jiang, Wen-Tao},
title = {Sutureless portal vein reconstruction in porcine orthotopic liver transplantation using a microvascular coupler: A randomized study with artificial intelligence-assisted histopathology},
journal = {World Journal of Gastrointestinal Surgery},
year = {2026},
volume = {18},
number = {8},
doi = {10.4240/wjgs.120360}
}
EUVIMED