COMPARISON OF MODIFIED CAROTID SINUS MASSAGE USING ULTRASONOGRAPHY WITH CONVENTIONAL CAROTID SINUS MASSAGE IN EMERGENCY DEPARTMENT
Genetics and Molecular Research · 06.05.2026
DOI: 10.4238/d7nhee51 ↗Kurz gefasst
Fachartikel in der Zeitschrift Genetics and Molecular Research, online erschienen am 06.05.2026. Verfasst von Zainab Nadeem und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Objectives
To compare the vagal response, measured by heart-rate reduction and R–R interval prolongation, produced by ultrasound-guided modified carotid sinus massage (CSM) versus conventional CSM in hemodynamically stable patients with acute supraventricular tachycardia (SVT) in the emergency department (ED). The study evaluated physiological response, not definitive clinical efficacy. Methodology: This prospective, open-label, blinded-endpoint randomized controlled trial was conducted at Central Park Teaching Hospital, Lahore (January 03, 2026 to April 03, 2026; IRB No. CPMC/IRB-No/1541). Patients aged 35–75 years with narrow-QRS (150 bpm, adjudicated by a blinded cardiologist, were randomized 1:1 using computer-generated permuted blocks with sealed opaque envelopes to ultrasound-guided modified CSM (Group A, n=125) or conventional CSM (Group B, n=125). In Group A, a 7.5–12 MHz linear probe identified the right carotid bulb at maximum dilation for a targeted 10-second unilateral pressure; Group B received right-sided palpation-guided pressure for 10 seconds. One attempt per patient was permitted. Primary outcomes were heart-rate and R–R interval change on continuous Lead II ECG, which were adjudicated blinded to allocation.
Results
Groups were balanced at baseline. Ultrasound-guided modified CSM produced significantly greater heart-rate reduction (53.2 ± 17.1 vs 25.8 ± 13.9 bpm; mean difference 27.4, 95% CI 23.2 to 31.6; p < 0.001; Cohen's d = 1.78) and R–R interval prolongation (0.272 ± 0.118 vs 0.148 ± 0.092 s; mean difference 0.124, 95% CI 0.098 to 0.150; p < 0.001; d = 1.12). No adverse events occurred (95% CI 0–1.5%).
Conclusion
Ultrasound-guided modified CSM produces a significantly greater vagal response and appears safe. Because these are surrogate endpoints, clinical superiority (SVT termination, rescue therapy, recurrence) requires confirmation in adequately powered multicenter trials before routine ED adoption.
Zitieren
APA
Nadeem, Z., Ilyas, M. A., Haq, E. U., Maqbool, M. A., & Yousaf, S. (2026). COMPARISON OF MODIFIED CAROTID SINUS MASSAGE USING ULTRASONOGRAPHY WITH CONVENTIONAL CAROTID SINUS MASSAGE IN EMERGENCY DEPARTMENT. Genetics and Molecular Research. https://doi.org/10.4238/d7nhee51
Vancouver
Nadeem Z, Ilyas MA, Haq EU, Maqbool MA, Yousaf S. COMPARISON OF MODIFIED CAROTID SINUS MASSAGE USING ULTRASONOGRAPHY WITH CONVENTIONAL CAROTID SINUS MASSAGE IN EMERGENCY DEPARTMENT. Genetics and Molecular Research. 2026. doi:10.4238/d7nhee51
BibTeX
@article{Nadeem2026,
author = {Nadeem, Zainab and Ilyas, Muhammad Ahmed and Haq, Ehtesham ul and Maqbool, M Arslan and Yousaf, Sadaf},
title = {COMPARISON OF MODIFIED CAROTID SINUS MASSAGE USING ULTRASONOGRAPHY WITH CONVENTIONAL CAROTID SINUS MASSAGE IN EMERGENCY DEPARTMENT},
journal = {Genetics and Molecular Research},
year = {2026},
doi = {10.4238/d7nhee51}
}
EUVIMED