EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis

Jean Louis Genicot, Telma Fonseca, Gary Kramer, André Wambersie

World Journal of Nuclear Science and Technology · 2011 · 01 (03) · 87-110

DOI: 10.4236/wjnst.2011.13013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift World Journal of Nuclear Science and Technology, 2011. Verfasst von Jean Louis Genicot und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Whole body counting (WBC) benefits from new types of detectors and methodologies. It has found applications in areas such as in medicine, protection of workers and of population. The design of a WBC facility should be tailored to the type of application. Monte Carlo calculations help to improve the reliability of the calibration of a facility, particularly for non-standard measurements (child, etc.), help in optimizing shielding of counting rooms, preventing large systematic errors and lowering detection limits. In vivo counting may be used to evaluate the distribution of radionuclides in organs for metabolic studies with multiple detectors or with a scan of the body. Reduction of detection levels by background reduction is limited. Improved sensitivity can be obtained by adapting the detector type and size to the measured photon energy. The benefit of comparison exercises and training courses are demonstrated. Further improvements in accuracy can be expected from cooperative works with other techniques: indirect methods (urines and faeces) and passive detectors placed correctly on the body can in the case of high levels of contamination can be used to improve the burden assessment.

Zitieren

APA

Genicot, J. L., Fonseca, T., Kramer, G., & Wambersie, A. (2011). Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis. World Journal of Nuclear Science and Technology, 01(03), 87-110. https://doi.org/10.4236/wjnst.2011.13013

Vancouver

Genicot JL, Fonseca T, Kramer G, Wambersie A. Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis. World Journal of Nuclear Science and Technology. 2011;01(03):87-110. doi:10.4236/wjnst.2011.13013

BibTeX
@article{Genicot2011,
  author = {Genicot, Jean Louis and Fonseca, Telma and Kramer, Gary and Wambersie, André},
  title = {Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis},
  journal = {World Journal of Nuclear Science and Technology},
  year = {2011},
  volume = {01},
  number = {03},
  pages = {87--110},
  doi = {10.4236/wjnst.2011.13013}
}
Kostenlos starten →