Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis
World Journal of Nuclear Science and Technology · 2011 · 01 (03) · 87-110
DOI: 10.4236/wjnst.2011.13013 ↗Kurz gefasst
Fachartikel in der Zeitschrift World Journal of Nuclear Science and Technology, 2011. Verfasst von Jean Louis Genicot und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Whole body counting (WBC) benefits from new types of detectors and methodologies. It has found applications in areas such as in medicine, protection of workers and of population. The design of a WBC facility should be tailored to the type of application. Monte Carlo calculations help to improve the reliability of the calibration of a facility, particularly for non-standard measurements (child, etc.), help in optimizing shielding of counting rooms, preventing large systematic errors and lowering detection limits. In vivo counting may be used to evaluate the distribution of radionuclides in organs for metabolic studies with multiple detectors or with a scan of the body. Reduction of detection levels by background reduction is limited. Improved sensitivity can be obtained by adapting the detector type and size to the measured photon energy. The benefit of comparison exercises and training courses are demonstrated. Further improvements in accuracy can be expected from cooperative works with other techniques: indirect methods (urines and faeces) and passive detectors placed correctly on the body can in the case of high levels of contamination can be used to improve the burden assessment.
Zitieren
APA
Genicot, J. L., Fonseca, T., Kramer, G., & Wambersie, A. (2011). Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis. World Journal of Nuclear Science and Technology, 01(03), 87-110. https://doi.org/10.4236/wjnst.2011.13013
Vancouver
Genicot JL, Fonseca T, Kramer G, Wambersie A. Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis. World Journal of Nuclear Science and Technology. 2011;01(03):87-110. doi:10.4236/wjnst.2011.13013
BibTeX
@article{Genicot2011,
author = {Genicot, Jean Louis and Fonseca, Telma and Kramer, Gary and Wambersie, André},
title = {Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis},
journal = {World Journal of Nuclear Science and Technology},
year = {2011},
volume = {01},
number = {03},
pages = {87--110},
doi = {10.4236/wjnst.2011.13013}
}