A Laplacian Surface Deformation and Optimization Based 3D Registration Algorithm for Image Guided Prostate Radiotherapy
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology · 2012
DOI: 10.4236/ijmpcero.2012.12006 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2012. Verfasst von Jinghao Zhou und 7 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To develop a fast landmark-based deformable registration method to capture the soft tissue transformation between the planning 3D CT images and treatment 3D cone-beam CT (CBCT) images for the adaptive external beam radiotherapy (EBRT). Method and Materials: The developed method was based on a global-to-local landmark-based deformable registration algorithm. The landmarks were first acquired by applying a fast segmentation method using the active shape model. The global registration method was applied to establish a registration framework. The Laplacian surface deformation (LSD) and Laplacian surface optimization (LSO) method were then employed for local deformation and remeshing respectively to reach an optimal registration solution. In LSD, the deformed mesh is generated by minimizing the quadratic energy to keep the shape and to move control points to the target position. In LSO, a mesh is reconstructed by minimizing the quadratic energy to smooth the object by minimizing the difference while keeping the landmarks unchanged. The method was applied on 8 EBRT prostate datasets. The distance and volume based estimators were used to evaluate the results. The target volumes delineated by physicians were used as gold standards in the evaluation.
Results
The entire segmentation and registration processing time was within 1 minute for all the datasets. The mean distance estimators ranged from 0.43 mm to 2.23 mm for the corresponding model points between the treatment CBCT images and the registered planning images. The mean overlap ratio ranged from 85.5% to 93.2% of the prostate volumes after registration. These results demonstrated reasonably good agreement between the developed method and the gold standards.
Conclusion
A novel and fast landmark-based deformable registration method is developed to capture the soft tissue transformation between the planning and treatment images for prostate target volumes. The results show that with the method the image registration and transformation can be completed within one minute and has the potential to be applied to real-time adaptive radiotherapy.
Zitieren
APA
Zhou, J., Zhang, S., Kim, S., Jabbour, S., Goyal, S., Haffty, B., Metaxas, D., & Yue, N. J. (2012). A Laplacian Surface Deformation and Optimization Based 3D Registration Algorithm for Image Guided Prostate Radiotherapy. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. https://doi.org/10.4236/ijmpcero.2012.12006
Vancouver
Zhou J, Zhang S, Kim S, Jabbour S, Goyal S, Haffty B, et al. A Laplacian Surface Deformation and Optimization Based 3D Registration Algorithm for Image Guided Prostate Radiotherapy. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. 2012. doi:10.4236/ijmpcero.2012.12006
BibTeX
@article{Zhou2012,
author = {Zhou, Jinghao and Zhang, Shaoting and Kim, Sung and Jabbour, Salma and Goyal, Sharad and Haffty, Bruce and Metaxas, Dimitris and Yue, Ning J.},
title = {A Laplacian Surface Deformation and Optimization Based 3D Registration Algorithm for Image Guided Prostate Radiotherapy},
journal = {International Journal of Medical Physics, Clinical Engineering and Radiation Oncology},
year = {2012},
doi = {10.4236/ijmpcero.2012.12006}
}
EUVIMED