EUVIMEDEUVIMED entdecken
Crossref

X-ray computed microtomography as a fundamental piece in the study of microcrinoids

Bruna Poatskievick-Pierezan, Andrew Scott Gale, Anderson Camargo Moreira, Bernardo Vazquez-Garcia, Lucas Del Mouro, Marcos Antonio Batista Dos Santos Filho, Simone Baecker-Fauth, Gerson Fauth

Acta Palaeontologica Polonica · 20.05.2026 · 71 (2) · 247-254

DOI: 10.4202/app.01328.2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Palaeontologica Polonica, online erschienen am 20.05.2026. Verfasst von Bruna Poatskievick-Pierezan und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study employs X-ray computed microtomography (micro-CT) to investigate the internal structures of microcrinoids, focusing on the roveacrinid Sergipecrinus reticulatus from the Aptian–Albian (112–115 Ma) of the Sergipe Basin, Brazil. For the first time, sub-basal balls were observed in situ and in three dimensions, representing the first 3D documentation of these internal structures in a microcrinoid cup. This constitutes both a methodological advance, the first use of micro-CT applied to this group, and a descriptive and taxonomic advance, as it reveals an unprecedented internal morphology. These structures, previously observed only under SEM and identified in fragments of other genera, might be hollow; however, micro-CT analysis reveals they are dense, containing only small and sub-resolution pores. This discovery suggests that their presence may be more widespread across the Roveacrinidae than previously thought, raising questions about their evolutionary and functional significance. As a cladistics trait, the presence of sub-basal balls contributes to the phylogenetic reconstruction of the family. Moreover, this study underscores the value of micro-CT in revealing detailed, non-destructive insights into microfossil morphology and proposes its broader application to uncover the internal structures of other genera within the Roveacrinidae.

Zitieren

APA

Poatskievick-Pierezan, B., Gale, A. S., Moreira, A. C., Vazquez-Garcia, B., Mouro, L. D., Filho, M. A. B. D. S., Baecker-Fauth, S., & Fauth, G. (2026). X-ray computed microtomography as a fundamental piece in the study of microcrinoids. Acta Palaeontologica Polonica, 71(2), 247-254. https://doi.org/10.4202/app.01328.2026

Vancouver

Poatskievick-Pierezan B, Gale AS, Moreira AC, Vazquez-Garcia B, Mouro LD, Filho MABDS, et al. X-ray computed microtomography as a fundamental piece in the study of microcrinoids. Acta Palaeontologica Polonica. 2026;71(2):247-254. doi:10.4202/app.01328.2026

BibTeX
@article{PoatskievickPierezan2026,
  author = {Poatskievick-Pierezan, Bruna and Gale, Andrew Scott and Moreira, Anderson Camargo and Vazquez-Garcia, Bernardo and Mouro, Lucas Del and Filho, Marcos Antonio Batista Dos Santos and Baecker-Fauth, Simone and Fauth, Gerson},
  title = {X-ray computed microtomography as a fundamental piece in the study of microcrinoids},
  journal = {Acta Palaeontologica Polonica},
  year = {2026},
  volume = {71},
  number = {2},
  pages = {247--254},
  doi = {10.4202/app.01328.2026}
}
Kostenlos starten →