EUVIMEDEUVIMED entdecken
Open Access

Assessment of Noninvasive Oxygen Saturation in Patients With COPD During Pulmonary Rehabilitation: Smartwatch versus Pulse Oximeter

Morten Pallisgaard Støve, Aske Hostrup Graversen, Johanne Sørensen

Respiratory Care · 2023

DOI: 10.4187/respcare.10760 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Respiratory Care, 2023. Verfasst von Morten Pallisgaard Støve und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy, University College of Northern Denmark, Aalborg, Denmark. mps@ucn.dk. Hauptthemen laut MEDLINE: Pulmonary Disease, Chronic Obstructive. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Patients with COPD can have hypoxemia; hence, monitoring peripheral S pO 2 during pulmonary rehabilitation is recommended. This study aimed to examine the accuracy of S pO 2 readings in patients with COPD as measured by wearable devices at rest and after physical exercise. METHODS: Thirty-six participants with COPD (20 women), ages 52–89 years, participated in this cross-sectional study. Oxygen saturation was concurrently measured by using the Contec Pulse Oximeter CMS50D as a comparator, and the Apple Watch Series 7 and the Garmin Vivosmart 4 at rest and immediately after the 30-s sit-to-stand test and the 6-min walk test (6MWT). RESULTS: For the Apple Watch, the root mean squared error showed a deviation of 3.5% at rest, 4.1% after the 30-s sit-to-stand test, and 3.9% after the 6MWT. The level of agreement was 2.8 ± 2.4 (7.6, –1.9) at rest, 3.1 ± 2.8 (8.6, –2.3) after the 30-s sit-to-stand test, and 2.8 ± 2.9 (8.6, –2.9) after the 6MWT. For the Garmin Vivosmart, the root mean squared error showed a deviation of 3.3% at rest, 6.1% after the 30-s sit-to-stand test, and 5.4% after the 6MWT. Level of agreement was 1.9 ± 2.7 (7.2, –3.3) at rest, 2.9 ± 5.4 (13.5, –7.7) after the 30-s sit-to-stand test, and 2.3 ± 5.0 (12.1, –7.4) after the 6MWT. The limits of agreement showed considerable measurement variance and a tendency for the devices to be less accurate at lower saturation levels. CONCLUSIONS: The Apple Watch Series 7 and Garmin Vivosmart 4 overestimated S pO 2 in participants with COPD when S pO 2 was < 95% and underestimated oxygen saturation when saturation was > 95%. These findings suggest that wearable devices should not be used to monitor oxygen saturation during pulmonary rehabilitation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary Disease, Chronic ObstructiveHumansFemaleCross-Sectional StudiesOxygen SaturationExercise TestOximetryOxygen

Stichwörter der Autor:innen

COPDWearable devicesoxygen saturationpulmonary rehabilitationrespiratory carevalidity

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Physiotherapy, University College of Northern Denmark, Aalborg, Denmark. mps@ucn.dk.
  • Centre for General Practice, Aalborg University, Aalborg East, Denmark.
  • Department of Physiotherapy, University College of Northern Denmark, Aalborg, Denmark.

Zitieren

APA

Støve, M. P., Graversen, A. H., & Sørensen, J. (2023). Assessment of Noninvasive Oxygen Saturation in Patients With COPD During Pulmonary Rehabilitation: Smartwatch versus Pulse Oximeter. Respiratory Care. https://doi.org/10.4187/respcare.10760

Vancouver

Støve MP, Graversen AH, Sørensen J. Assessment of Noninvasive Oxygen Saturation in Patients With COPD During Pulmonary Rehabilitation: Smartwatch versus Pulse Oximeter. Respiratory Care. 2023. doi:10.4187/respcare.10760

BibTeX
@article{Stve2023,
  author = {Støve, Morten Pallisgaard and Graversen, Aske Hostrup and Sørensen, Johanne},
  title = {Assessment of Noninvasive Oxygen Saturation in Patients With COPD During Pulmonary Rehabilitation: Smartwatch versus Pulse Oximeter},
  journal = {Respiratory Care},
  year = {2023},
  doi = {10.4187/respcare.10760}
}
Kostenlos starten →