Use of EndoAnchors during index endovascular aortic aneurysm repair in patients with hostile proximal aortic neck anatomy
Bratislava Medical Journal · 2024
DOI: 10.4149/bll_2024_52 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bratislava Medical Journal, 2024. Verfasst von Jozef Sivak und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Endovascular Procedures, Aortic Aneurysm, Abdominal, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 2-mal zitiert (Crossref).
Abstract (Originalsprache)
PURPOSE: Standard endovascular aortic aneurysm repair (EVAR) is sometimes the only treatment option for patients with hostile aortic neck anatomy, but it carries an increased risk of both early and late procedure-related complications. The aim of this study was to report on single-center experience with the Heli-FX EndoAnchors (Medtronic, Santa Rosa, CA) as an adjunctive procedure to endovascular aneurysm repair (EVAR) for prevention and perioperative treatment of proximal neck complications in patients with hostile neck anatomy. MATERIALS AND METHODS: A single-centre, retrospective study evaluating 24 consecutive patients treated with EndoAnchors during the index EVAR procedure between November 2018 and August 2021. EndoAnchor implantation was indicated for cases with hostile proximal aortic neck anatomy characterised by the presence of at least one of the following parameters: length of 28 mm, angle of >60°, circumferential thrombus/calcification involving ≥50%, and reverse taper. RESULTS: Median follow-up period was 22.5 months (IQR 2-31.5 months) with no aneurysm-related death, rupture, or conversion to open surgical repair during the follow-up. The procedural success rate was 100%, with no type Ia endoleak at the completion angiography. A mean of 7 EndoAnchors was used per patient (range 4-12). There were no EndoAnchor fractures and dislocations or stent graft fabric damage due to anchor implants. Twenty-three patients (95.8%) remained free of type Ia endoleak and migration on follow-up imaging. Aneurysm sac regression was observed in 13 patients (54.1%), while in 8 patients (33.3%) the sac remained stable. Sac enlargement was present in 1 patient (4.2%) due to late type Ia endoleak. Two patients were lost to the follow-up immediately after the procedure. Between two groups of patients (sac regression versus failure to regress), the larger initial diameter of the proximal neck was the only significant independent factor associated with a lower possibility of sac regression (p= 0,021). CONCLUSIONS: The use of EndoAnchors during the index EVAR procedure in cases with challenging aortic neck anatomy with or without perioperative type Ia endoleak was associated with good midterm results and led to sac regression in most of the patients (Tab. 4, Fig. 3, Ref. 31).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Zitieren
APA
Sivak, J., Suchac, M., Daxner, M., Kmetkova, K., Sykora, J., Zapletalova, J., Zelenak, K., & Simkova, I. (2024). Use of EndoAnchors during index endovascular aortic aneurysm repair in patients with hostile proximal aortic neck anatomy. Bratislava Medical Journal. https://doi.org/10.4149/bll_2024_52
Vancouver
Sivak J, Suchac M, Daxner M, Kmetkova K, Sykora J, Zapletalova J, et al. Use of EndoAnchors during index endovascular aortic aneurysm repair in patients with hostile proximal aortic neck anatomy. Bratislava Medical Journal. 2024. doi:10.4149/bll_2024_52
BibTeX
@article{Sivak2024,
author = {Sivak, Jozef and Suchac, Martin and Daxner, Maros and Kmetkova, Katarina and Sykora, Jan and Zapletalova, Jana and Zelenak, Kamil and Simkova, Iveta},
title = {Use of EndoAnchors during index endovascular aortic aneurysm repair in patients with hostile proximal aortic neck anatomy},
journal = {Bratislava Medical Journal},
year = {2024},
doi = {10.4149/bll_2024_52}
}
EUVIMED