Comparative Study of Mastectomy Using Conventional Techniques, Multiport and Single-Port Robotic Surgical Systems
Cancer Research and Treatment · 2026
DOI: 10.4143/crt.2025.115 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Cancer Research and Treatment, 2026. Verfasst von Jeea Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Graduate School of Medicine, Yonsei University College of Medicine, Seoul, Korea. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Breast Neoplasms, Mastectomy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: Intuitive Surgical.
Abstract (Originalsprache)
Purpose
Oncologic and surgical outcomes of robot-assisted nipple-sparing mastectomy (RNSM) compared to conventional nipple-sparing mastectomy (CNSM) is under investigation. This study compared the clinical outcomes of recurrence-free survival and postoperative complication after RNSM and CNSM.Materials and Methods We retrospectively reviewed data of 401 patients who underwent da Vinci Si/Xi/SP-assisted RNSM or CNSM with immediate reconstruction between November 2016 and November 2020 at a single institute. Oncological outcomes were collected until March 2022. Primary endpoints were long-term outcomes, such as local recurrence, distant metastasis, disease-free survival, overall survival, and postoperative complications, while secondary endpoints were pathology results, and oncological outcomes.
Results
Patients underwent RNSM (n=162) or CNSM (n=239). Of RNSM cases, 9 (5.6%) were performed using the da Vinci Si System, 96 (59.3%) using the da Vinci Xi System, and 57 (35.2%) using the da Vinci SP System. No significant difference in recurrence-free survival was found between the RNSM and CNSM group, and both groups had a median follow-up of 37 months. The recurrence rate in RNSM patients after a median follow-up of 24.5 months was 3.8%, compared with 5.9% in CNSM patients after a median follow-up of 42 months. No difference in recurrence was seen among RNSM patients with respect to surgical systems (multiport vs. SP, p =0.136). In addition, grade III postoperative complication rate was lower in patients with RNSM than in those with CNSM. Transfusion was only applied in 6.2% of patients.
Conclusion
Robot-assisted surgical systems can be safely used to perform nipple-sparing mastectomy in patients with early breast cancer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, Graduate School of Medicine, Yonsei University College of Medicine, Seoul, Korea.
- Department of Surgery, Uijeongbu Eulji Medical Center, Eulji University, Uijeongbu, Korea.
- Department of Surgery, Yonsei University College of Medicine, Seoul, Korea.
- Department of Biostatistics and Computing, Yonsei University College of Medicine, Seoul, Korea.
- Department of Surgery, Cancer Prevention Center, Yonsei Cancer Center, Severance Hospital, Yonsei University Health System, Korea.
- Institute for Innovation in Digital Healthcare, Yonsei University, Korea.
Förderung
- Intuitive Surgical
Zitieren
APA
Lee, J., Go, J., Lee, S. J., Kwon, Y., Kim, N. H., Kim, J. Y., & Park, H. S. (2026). Comparative Study of Mastectomy Using Conventional Techniques, Multiport and Single-Port Robotic Surgical Systems. Cancer Research and Treatment. https://doi.org/10.4143/crt.2025.115
Vancouver
Lee J, Go J, Lee SJ, Kwon Y, Kim NH, Kim JY, et al. Comparative Study of Mastectomy Using Conventional Techniques, Multiport and Single-Port Robotic Surgical Systems. Cancer Research and Treatment. 2026. doi:10.4143/crt.2025.115
BibTeX
@article{Lee2026,
author = {Lee, Jeea and Go, Jieon and Lee, Suk Jun and Kwon, Yonghan and Kim, Nam Hee and Kim, Jee Ye and Park, Hyung Seok},
title = {Comparative Study of Mastectomy Using Conventional Techniques, Multiport and Single-Port Robotic Surgical Systems},
journal = {Cancer Research and Treatment},
year = {2026},
doi = {10.4143/crt.2025.115}
}
EUVIMED