EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Inter-device agreement between spectral domain optical coherence tomography, ultrasound biomicroscopy, and gonioscopy in evaluating the iridocorneal angle in normotensive dogs

Su An Kim iD, Jaeho Shim iD, Seonmi Kang iD, Kangmoon Seo iD

Journal of Veterinary Science · 2023

DOI: 10.4142/jvs.22241 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Science, 2023. Verfasst von Su An Kim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, …. Hauptthemen laut MEDLINE: Microscopy, Acoustic, Tomography, Optical Coherence. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Research Institute for Veterinary Science, College of Veterinary Medicine, Seoul National University, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: There has not been a thoroughly reported study of the comparison between spectral domain-optical coherence tomography (SD-OCT) with both ultrasound biomicroscopy (UBM) and gonioscopy on the evaluation of the iridocorneal angle (ICA) in dogs. OBJECTIVES: To investigate the diagnostic value of SD-OCT for the early detection of narrowing ICA by comparing and assessing inter-device agreement in anterior chamber angle (ACA) measurements obtained by SD-OCT and UBM, and ICA evaluations by gonioscopy. METHODS: A total of 28 eyes from 28 client-owned dogs with normal intraocular pressure were included for examination. The ACA and angle opening distance (AOD) were measured from the SD-OCT and UBM images, and gonioscopy images were analyzed using the ICA grade and ZibWest angle index. RESULTS: The mean ACA and AOD for SD-OCT were 28.31° ± 5.37° and 658.42 ± 219.90 µm, and for UBM, 28.34° ± 5.82° and 859.29 ± 221.80 µm, respectively. The mean difference in ACA between the average values of SD-OCT and UBM measurements was 0.03° with a 95% limit of agreement (LoA) span of 16.2°, indicating positive agreement; that in AOD was 200.85 µm with a 95% LoA span of 1,110.95 µm, indicating poor agreement. The Pearson correlation coefficient of the ACA of SD-OCT and ZibWest indices of gonioscopy was 0.624, indicating strong agreement; that of UBM and gonioscopy was 0.43, indicating moderate agreement. CONCLUSIONS: SD-OCT is well tolerated by canine patients due to its non-contact method and might be an alternative option for early screening of ICA narrowing in clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Microscopy, AcousticTomography, Optical CoherenceDogsAnimalsGonioscopyEyeBlood Pressure

Stichwörter der Autor:innen

Diagnosisglaucomamass screeningoptical imagingtherapeutics

Autor:innen und Institutionen

  • Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul 08826, Korea.
  • Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul 08826, Korea. kmseo@snu.ac.kr.

ORCID-Profile: Su An Kim, Jaeho Shim, Seonmi Kang, Kangmoon Seo

Förderung

  • Research Institute for Veterinary Science, College of Veterinary Medicine, Seoul National University
  • National Research Foundation of Korea

Zitieren

APA

Kim, S. A., Shim, J., Kang, S., & Seo, K. (2023). Inter-device agreement between spectral domain optical coherence tomography, ultrasound biomicroscopy, and gonioscopy in evaluating the iridocorneal angle in normotensive dogs. Journal of Veterinary Science. https://doi.org/10.4142/jvs.22241

Vancouver

Kim SA, Shim J, Kang S, Seo K. Inter-device agreement between spectral domain optical coherence tomography, ultrasound biomicroscopy, and gonioscopy in evaluating the iridocorneal angle in normotensive dogs. Journal of Veterinary Science. 2023. doi:10.4142/jvs.22241

BibTeX
@article{Kim2023,
  author = {Kim, Su An and Shim, Jaeho and Kang, Seonmi and Seo, Kangmoon},
  title = {Inter-device agreement between spectral domain optical coherence tomography, ultrasound biomicroscopy, and gonioscopy in evaluating the iridocorneal angle in normotensive dogs},
  journal = {Journal of Veterinary Science},
  year = {2023},
  doi = {10.4142/jvs.22241}
}
Kostenlos starten →