Comparing dusting and fragmenting efficiency using the new SuperPulsed thulium fiber laser versus a 120 W Holmium:YAG laser
Investigative and Clinical Urology · 2023
DOI: 10.4111/icu.20230071 ↗Kurz gefasst
Fachartikel in der Zeitschrift Investigative and Clinical Urology, 2023. Verfasst von Ben H Chew und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urological Sciences, University of British Columbia, Stone Centre at Vancouver General Hospital, Vancouver, BC, Canada. ben.chew@ubc.ca. Hauptthemen laut MEDLINE: Lasers, Solid-State, Lithotripsy, Laser, Lithotripsy. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
PURPOSE: Holmium:YAG laser lithotripsy requires high amperage power and has an upper limit of frequency and a minimal fiber size. The technology utilizing thulium-doped fiber offers low pulse energy settings and high pulse frequencies up to 2,400 Hz. We compared the novel SuperPulsed thulium fiber laser (SOLTIVE™; Olympus) to a commercially available 120 W Ho:YAG laser. MATERIALS AND METHODS: Bench-top testing was conducted with 125 mm3 standardized BegoStones (Bego USA). Time to ablate the stone into particles 2 mm remained using SOLTIVE™ than Ho:YAG laser (2.10 vs. 7.20 fragments). After delivering 2 kJ, dusting (1.05±0.08 mg/s) was faster using SOLTIVE™ (0.1 J 200 Hz short pulse) than 120 W 0.46±0.09 mg/s (0.3 J 70 Hz Moses) (p=0.005). SOLTIVE™ (0.1 J 200 Hz) produced more dust particles
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Urological Sciences, University of British Columbia, Stone Centre at Vancouver General Hospital, Vancouver, BC, Canada. ben.chew@ubc.ca.
- Department of Urology, Yonsei University College of Medicine, Seoul, Korea.
- Department of Urology, King Abdulaziz University, Jeddah, Saudi Arabia.
- Department of Urological Sciences, University of British Columbia, Stone Centre at Vancouver General Hospital, Vancouver, BC, Canada.
- Department of Urology, The Ohio State University Wexner Medical Center, Columbus, OH, USA.
- Department of Urology, University of Kansas Medical Center, Kansas City, KS, USA.
ORCID-Profile: Ben H Chew, Kyo Chul Koo, Abdulghafour Halawani, Colin J Lundeen, Bodo E Knudsen, Wilson R Molina
Zitieren
APA
Chew, B. H., Koo, K. C., Halawani, A., Lundeen, C. J., Knudsen, B. E., & Molina, W. R. (2023). Comparing dusting and fragmenting efficiency using the new SuperPulsed thulium fiber laser versus a 120 W Holmium:YAG laser. Investigative and Clinical Urology. https://doi.org/10.4111/icu.20230071
Vancouver
Chew BH, Koo KC, Halawani A, Lundeen CJ, Knudsen BE, Molina WR. Comparing dusting and fragmenting efficiency using the new SuperPulsed thulium fiber laser versus a 120 W Holmium:YAG laser. Investigative and Clinical Urology. 2023. doi:10.4111/icu.20230071
BibTeX
@article{Chew2023,
author = {Chew, Ben H and Koo, Kyo Chul and Halawani, Abdulghafour and Lundeen, Colin J and Knudsen, Bodo E and Molina, Wilson R},
title = {Comparing dusting and fragmenting efficiency using the new SuperPulsed thulium fiber laser versus a 120 W Holmium:YAG laser},
journal = {Investigative and Clinical Urology},
year = {2023},
doi = {10.4111/icu.20230071}
}
EUVIMED