Comparison of two bedside ultrasound techniques and standard methods for confirmation of endotracheal tube insertion in intensive care patients, a cross-sectional observational study
Tanta Medical Journal · 2026-07 · 54 (3) · 510-515
DOI: 10.4103/tmj.tmj_83_25 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Tanta Medical Journal, online erschienen am 24.07.2026. Verfasst von Eman E.I. Abuharga und 3 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Themen: Intensivpflege
Abstract (Originalsprache)
Background
Endotracheal intubation (ETI) and suprasternal and subxiphoid ultrasonography (US) are medical procedures used to verify endotracheal tube (ETT) placement in intensive care patients.
Aim
This work aimed to verify the appropriate implantation of ETT in intensive care patients by predicting the specificity and sensitivity of US by suprasternal and subxiphoid methods compared to standard methods. Patients and methods This cross-sectional observational study included 70 patients who underwent ETI. ETI and evaluation by capnography were utilized for the standard monitoring of patients. The gold standard method was regarded as positive if all or two of the three methods, which are chest auscultation, capnography, and observation of chest inflation, were positive (verifying correct tube positioning); otherwise, the results were considered negative. The true positive result was determined when the gold standard method produced a positive result, and the true tube placement was verified by suprasternal or subxiphoid sonography.
Results
Elapsed time to confirm endotracheal position was significantly higher in standard methods than (suprasternal notch US and subxiphoid US), and was significantly higher in subxiphoid US than suprasternal notch ( P
Zitieren
APA
Abuharga, E. E., Elshmaa, N. S., Abdelkader, S. F., & El-Abd, S. S. (2026). Comparison of two bedside ultrasound techniques and standard methods for confirmation of endotracheal tube insertion in intensive care patients, a cross-sectional observational study. Tanta Medical Journal, 54(3), 510-515. https://doi.org/10.4103/tmj.tmj_83_25
Vancouver
Abuharga EE, Elshmaa NS, Abdelkader SF, El-Abd SS. Comparison of two bedside ultrasound techniques and standard methods for confirmation of endotracheal tube insertion in intensive care patients, a cross-sectional observational study. Tanta Medical Journal. 2026;54(3):510-515. doi:10.4103/tmj.tmj_83_25
BibTeX
@article{Abuharga2026,
author = {Abuharga, Eman E.I. and Elshmaa, Nagat S. and Abdelkader, Shaimaa F. and El-Abd, Sherif S.H.},
title = {Comparison of two bedside ultrasound techniques and standard methods for confirmation of endotracheal tube insertion in intensive care patients, a cross-sectional observational study},
journal = {Tanta Medical Journal},
year = {2026},
volume = {54},
number = {3},
pages = {510--515},
doi = {10.4103/tmj.tmj_83_25}
}
EUVIMED