EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

NIM TriVantage™ electromyogram endotracheal tube kinking and the preclusion using a tube stand in patients undergoing thyroid surgery

Kensuke Suzuki, Shingo Kawashima, Atsushi Kobayashi, Tetsuro Kimura, Yoshiki Nakajima, Hiroyuki Kinoshita

Saudi Journal of Anaesthesia · 2026-07 · 20 (3) · 632-637

DOI: 10.4103/sja.sja_324_26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Saudi Journal of Anaesthesia, online erschienen am 02.07.2026. Verfasst von Kensuke Suzuki und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Intensive Care, Hamamatsu University School of Medicine, Hamamatsu, Japan. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The NIM TriVantage™ electromyogram endotracheal tube (NIM [Nerve Integrity Monitoring] tube) is positioned at the midline of the mouth, as the electrodes must attach to both sides of the vocal cords for neural monitoring during thyroid surgery. The tube possibly kinks below the slip joint, resulting in ventilatory disturbance. We examined whether kinking of the NIM tube altered ventilation in a simulation model and assessed whether using a tube stand during thyroid surgery prevented such kinking and associated ventilatory instability.

Methods

We assessed the impact of bending warmed (32°C) NIM tubes (7.0- and 8.0-mm ID, n = 10 per group) on airway pressure and measured tidal volume within a simulator. Additionally, we investigated whether a custom-designed tube stand could mitigate ventilatory impairment when employing a midline-fixed NIM tube in patients undergoing thyroid surgery.

Results

In a simulator, 75° bending of the NIM (7.0 mm) tube significantly augmented airway pressure (31 [28 to 34] cmH 2 O, median [IQR], P < 0.001), and 60° and 75° bending of it caused a slight, but significant decrease in the measured tidal volume compared with 0° bending. Using our custom tube stand prevented kinking of the 7.0-mm NIM tube, with no clinically meaningful changes in airway pressure or delivered tidal volume during surgery.

Conclusions

The NIM (7.0 mm) tube is vulnerable to kinking-induced ventilatory impairment in the clinical setting, and a tube stand prevents this issue. We recommend using a tube stand during thyroid surgery to ensure safe and effective neural monitoring.

Schlagwörter

Stichwörter der Autor:innen

Electromyographyequipment and suppliesequipment failureintubationsurgical proceduresthyroid gland

Autor:innen und Institutionen

  • Department of Anesthesiology and Intensive Care, Hamamatsu University School of Medicine, Hamamatsu, Japan.
  • Department of Anesthesiology, Seirei Mikatahara General Hospital, Hamamatsu, Japan.
  • Department of Dental Anesthesiology, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan.

Zitieren

APA

Suzuki, K., Kawashima, S., Kobayashi, A., Kimura, T., Nakajima, Y., & Kinoshita, H. (2026). NIM TriVantage™ electromyogram endotracheal tube kinking and the preclusion using a tube stand in patients undergoing thyroid surgery. Saudi Journal of Anaesthesia, 20(3), 632-637. https://doi.org/10.4103/sja.sja_324_26

Vancouver

Suzuki K, Kawashima S, Kobayashi A, Kimura T, Nakajima Y, Kinoshita H. NIM TriVantage™ electromyogram endotracheal tube kinking and the preclusion using a tube stand in patients undergoing thyroid surgery. Saudi Journal of Anaesthesia. 2026;20(3):632-637. doi:10.4103/sja.sja_324_26

BibTeX
@article{Suzuki2026,
  author = {Suzuki, Kensuke and Kawashima, Shingo and Kobayashi, Atsushi and Kimura, Tetsuro and Nakajima, Yoshiki and Kinoshita, Hiroyuki},
  title = {NIM TriVantage™ electromyogram endotracheal tube kinking and the preclusion using a tube stand in patients undergoing thyroid surgery},
  journal = {Saudi Journal of Anaesthesia},
  year = {2026},
  volume = {20},
  number = {3},
  pages = {632--637},
  doi = {10.4103/sja.sja_324_26}
}
Kostenlos starten →