EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparative efficacy of high-flow nasal cannula versus conventional oxygen delivery during procedural sedation for ovum pickup in assisted reproductive technology

Vishal Mohan, Bhavna Hooda, Shalendra Singh, Deepak Dwivedi, Josemine Davis

Saudi Journal of Anaesthesia · 2026-07 · 20 (3) · 545-549

DOI: 10.4103/sja.sja_180_26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Saudi Journal of Anaesthesia, online erschienen am 02.07.2026. Verfasst von Vishal Mohan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Critical Care, Army Hospital (R and R), New Delhi, India. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Procedural sedation during ovum pickup (OPU) is often associated with transient hypoxemia and airway interventions. High-flow nasal cannula (HFNC) therapy may improve oxygenation during sedated procedures, but evidence in assisted reproductive techniques remains limited. This study compares HFNC with conventional low-flow oxygen (CFO) in maintaining oxygenation during OPU. Materials and Methods: In this randomized controlled trial, 220 women undergoing OPU under propofol sedation were allocated to either CFO (Group C; n = 110) or HFNC (Group H; n = 110). The outcomes assessed included desaturation events, hemodynamic parameters, depth of sedation, airway interventions, and adverse events.

Results

Hemodynamic and respiratory parameters remained stable and comparable between groups throughout the procedure and recovery. Desaturation events were more frequent in Group C ( P = 0.161), and the need for rescue escalation of oxygen therapy was significantly higher in this group compared with the group H (13.6% vs. 5.5%; P = 0.03). Total Propofol consumption, procedure duration, recovery time, and adverse events were similar, with high patient and physician satisfaction in both groups.

Conclusion

HFNC provides a safe and effective alternative to CFO therapy during procedural sedation for OPU, significantly reducing the need for oxygen escalation without affecting hemodynamic stability, sedation depth, or recovery. Its routine use may enhance respiratory safety in sedated reproductive procedures.

Schlagwörter

Stichwörter der Autor:innen

Assisted reproductive technologyconscious sedationhigh-flow nasal cannula oxygen therapyhypoxiain vitro fertilizationoxygen inhalation therapysedation

Autor:innen und Institutionen

  • Department of Anesthesiology and Critical Care, Army Hospital (R and R), New Delhi, India.
  • Department of Anaesthesiology and Critical Care, Field Hospital, Siliguri, West Bengal, India.

Zitieren

APA

Mohan, V., Hooda, B., Singh, S., Dwivedi, D., & Davis, J. (2026). Comparative efficacy of high-flow nasal cannula versus conventional oxygen delivery during procedural sedation for ovum pickup in assisted reproductive technology. Saudi Journal of Anaesthesia, 20(3), 545-549. https://doi.org/10.4103/sja.sja_180_26

Vancouver

Mohan V, Hooda B, Singh S, Dwivedi D, Davis J. Comparative efficacy of high-flow nasal cannula versus conventional oxygen delivery during procedural sedation for ovum pickup in assisted reproductive technology. Saudi Journal of Anaesthesia. 2026;20(3):545-549. doi:10.4103/sja.sja_180_26

BibTeX
@article{Mohan2026,
  author = {Mohan, Vishal and Hooda, Bhavna and Singh, Shalendra and Dwivedi, Deepak and Davis, Josemine},
  title = {Comparative efficacy of high-flow nasal cannula versus conventional oxygen delivery during procedural sedation for ovum pickup in assisted reproductive technology},
  journal = {Saudi Journal of Anaesthesia},
  year = {2026},
  volume = {20},
  number = {3},
  pages = {545--549},
  doi = {10.4103/sja.sja_180_26}
}
Kostenlos starten →