Thermal conduction of three rotary gutta-percha cones using a two-dimensional axisymmetric transient heat conduction simulation: An in vitro study
Saudi Endodontic Journal · 2026-05 · 16 (2) · 176-185
DOI: 10.4103/sej.sej_72_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Saudi Endodontic Journal, online erschienen am 25.04.2026. Verfasst von Ka Ming (Henry) Fan und 4 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
System B is a widely used endodontic heat source for warm vertical condensation (WVC) during root canal obturation. As gutta-percha (GP) remains the most commonly used obturation material, this study evaluated the thermal conduction characteristics of three rotary GP cones with different tapers using both experimental measurements and thermal modeling. Materials and Methods: Root canal treatment was performed on eight extracted, single-rooted maxillary central incisors. The thermal conductivity and diffusivity of ProTaper NEXT, WaveOne Gold (W1G), and ProTaper Universal (PTU) GP cones were measured using a modified transient plane source technique. Temperature changes were recorded at 0.5 mm, 2.5 mm, and 10.5 mm along the cone using K-type thermocouples and the System B heat source. A two-dimensional axisymmetric transient heat conduction simulation was performed to validate experimental results. The output temperature of the System B tip was also evaluated for consistency and accuracy. Data were statistically analyzed.
Results
PTU exhibited the highest thermal conductivity (1.07 W/m·K) and diffusivity (6.0 × 10 -7 m²/s), while W1G showed the greatest mean maximum temperature and temperature rise at 0.5 mm and 2.5 mm ( P < 0.05). Thermal simulation showed that up to 0.9 mm of the GP cone reached the softening temperature (≥65 °C). Taper size significantly influenced both the extent and direction of heat conduction.
Conclusions
GP cone composition and taper significantly influence thermal conduction during WVC. Cones with low zinc oxide content showed superior heat transmission, and greater taper enhanced apical heat flow.
Zitieren
APA
Fan, K. M. H., Woodfield, P., Lee, R., Dung, S., & George, R. (2026). Thermal conduction of three rotary gutta-percha cones using a two-dimensional axisymmetric transient heat conduction simulation: An in vitro study. Saudi Endodontic Journal, 16(2), 176-185. https://doi.org/10.4103/sej.sej_72_25
Vancouver
Fan KMH, Woodfield P, Lee R, Dung S, George R. Thermal conduction of three rotary gutta-percha cones using a two-dimensional axisymmetric transient heat conduction simulation: An in vitro study. Saudi Endodontic Journal. 2026;16(2):176-185. doi:10.4103/sej.sej_72_25
BibTeX
@article{Fan2026,
author = {Fan, Ka Ming (Henry) and Woodfield, Peter and Lee, Richard and Dung, Shelley and George, Roy},
title = {Thermal conduction of three rotary gutta-percha cones using a two-dimensional axisymmetric transient heat conduction simulation: An in vitro study},
journal = {Saudi Endodontic Journal},
year = {2026},
volume = {16},
number = {2},
pages = {176--185},
doi = {10.4103/sej.sej_72_25}
}
EUVIMED