Comparative evaluation of accuracy and efficiency of two techniques of guided root-end resection using a dynamic navigation system – An in vitro study
Saudi Endodontic Journal · 2026-05 · 16 (2) · 223-230
DOI: 10.4103/sej.sej_191_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Saudi Endodontic Journal, online erschienen am 25.04.2026. Verfasst von Dasari Lokesh und 5 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Dynamic navigation technology is revolutionizing endodontic microsurgery by enabling real-time surgical guidance and improved procedural accuracy. The incorporation of trephine burs and multiple drill techniques has further enhanced the precision and predictability of root-end resections. Within this context, the present study aimed to compare the accuracy and efficiency of two dynamic navigation-assisted root-end resection techniques. Materials and Methods: Thirty standardized three-dimensionally printed maxillary central incisors were fabricated and randomly allocated into three groups ( n = 10 each): freehand with trephine (FH-T), dynamic navigation system (DNS)-assisted trephine, and DNS -assisted sequential drills. Preoperative cone-beam computed tomography (CBCT) scans were obtained, and root-end resection was performed following the respective group protocols. Postoperative CBCT scans were then acquired to evaluate accuracy parameters, including entry, apex, and angular deviations, using EvaluNav ® software. The operation time for each procedure was recorded to assess efficiency. Data were analyzed using one-way analysis of variance with Tukey’s post hoc test ( P ≤ 0.05).
Results
The DNS-assisted trephine approach demonstrated a significantly lower mean entry deviation, apex deviation, and angular deviation, in addition to the shortest operation time compared to the FH-T approach.
Conclusion
The DNS-assisted trephine approach demonstrated superior accuracy in entry, apex, and angular deviations, along with the shortest operation time, indicating enhanced efficiency compared to the freehand trephine approach.
Zitieren
APA
Lokesh, D., Varma, K. M., Mavidi, J. B., Satish, R. K., Dalavai, P., & Jatoth, K. (2026). Comparative evaluation of accuracy and efficiency of two techniques of guided root-end resection using a dynamic navigation system – An in vitro study. Saudi Endodontic Journal, 16(2), 223-230. https://doi.org/10.4103/sej.sej_191_25
Vancouver
Lokesh D, Varma KM, Mavidi JB, Satish RK, Dalavai P, Jatoth K. Comparative evaluation of accuracy and efficiency of two techniques of guided root-end resection using a dynamic navigation system – An in vitro study. Saudi Endodontic Journal. 2026;16(2):223-230. doi:10.4103/sej.sej_191_25
BibTeX
@article{Lokesh2026,
author = {Lokesh, Dasari and Varma, K. Madhu and Mavidi, Jagapathi Babu and Satish, R. Kalyan and Dalavai, Praveen and Jatoth, Krishnaveni},
title = {Comparative evaluation of accuracy and efficiency of two techniques of guided root-end resection using a dynamic navigation system – An in vitro study},
journal = {Saudi Endodontic Journal},
year = {2026},
volume = {16},
number = {2},
pages = {223--230},
doi = {10.4103/sej.sej_191_25}
}
EUVIMED