Assessing cone-beam computed tomography artifact reduction using a cotton spacer for improved detection of vertical root fractures in endodontically treated teeth: An in vitro study

Vaishali Chhabra, Aishwarya Sukumaran Nair, Hannah Haneef, Manuel Sebastian Thomas, Ceena Denny, Ravindranath Vineetha, P. P. Jagadish Rao, Srikant Natarajan

Saudi Endodontic Journal · 2026-05 · 16 (2) · 186-193

DOI: 10.4103/sej.sej_149_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Saudi Endodontic Journal, online erschienen am 25.04.2026. Verfasst von Vaishali Chhabra und 7 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The detection of vertical root fractures (VRFs) in root canal-treated teeth with metallic posts is challenging because of beam hardening artifacts in cone-beam computed tomography (CBCT) images. This in vitro study aimed to evaluate whether placing a cotton spacer could reduce artifacts and improve diagnostic accuracy in CBCT detection of VRFs. Materials and Methods: Twenty single-rooted human teeth were selected and endodontically treated, and metallic posts were placed. VRFs were artificially induced in a subset. Teeth were mounted in dry human mandibles with simulated soft tissue and scanned via CBCT, both with and without a cotton spacer placed between the mandible and phantom head. Two observers independently evaluated the scans in the axial, coronal, and sagittal planes. Artifact reduction was quantified via ImageJ software. Diagnostic performance was assessed via sensitivity, specificity, predictive values, and Cohen’s kappa for inter- and intraobserver reliability. Statistical significance was tested via one-sample t -tests and Shapiro–Wilk tests.

Results

Interobserver and intraobserver agreement improved with spacer use. The diagnostic accuracy for detecting VRFs improved from 65% (without spacers) to 80% (with spacers). The sensitivity increased from 40% to 60%, and the specificity increased from 90% to 100%. The use of a cotton spacer significantly reduced artifacts by an average of 25.19% ( P < 0.001).

Conclusion

Incorporating a cotton spacer during CBCT imaging significantly reduces artifacts and improves both diagnostic accuracy and observer reliability in detecting VRFs in teeth with metallic posts.

Zitieren

APA

Chhabra, V., Nair, A. S., Haneef, H., Thomas, M. S., Denny, C., Vineetha, R., Rao, P. P. J., & Natarajan, S. (2026). Assessing cone-beam computed tomography artifact reduction using a cotton spacer for improved detection of vertical root fractures in endodontically treated teeth: An in vitro study. Saudi Endodontic Journal, 16(2), 186-193. https://doi.org/10.4103/sej.sej_149_25

Vancouver

Chhabra V, Nair AS, Haneef H, Thomas MS, Denny C, Vineetha R, et al. Assessing cone-beam computed tomography artifact reduction using a cotton spacer for improved detection of vertical root fractures in endodontically treated teeth: An in vitro study. Saudi Endodontic Journal. 2026;16(2):186-193. doi:10.4103/sej.sej_149_25

BibTeX
@article{Chhabra2026,
  author = {Chhabra, Vaishali and Nair, Aishwarya Sukumaran and Haneef, Hannah and Thomas, Manuel Sebastian and Denny, Ceena and Vineetha, Ravindranath and Rao, P. P. Jagadish and Natarajan, Srikant},
  title = {Assessing cone-beam computed tomography artifact reduction using a cotton spacer for improved detection of vertical root fractures in endodontically treated teeth: An in vitro study},
  journal = {Saudi Endodontic Journal},
  year = {2026},
  volume = {16},
  number = {2},
  pages = {186--193},
  doi = {10.4103/sej.sej_149_25}
}
Kostenlos starten →